• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Determinants of radiation dose during right transradial access: Insights from the RAD-MATRIX study.
 

Determinants of radiation dose during right transradial access: Insights from the RAD-MATRIX study.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.111772
Publisher DOI
10.1016/j.ahj.2017.10.014
PubMed ID
29421003
Description
BACKGROUND

The RAD-MATRIX trial reported a large operator radiation exposure variability in right radial percutaneous coronary procedures. The reasons of these differences are not well understood. Our aim was to appraise the determinants of operator radiation exposure during coronary right transradial procedures.

METHODS

Patient arrangement during transradial intervention was investigated across operators involved in the RAD-MATRIX trial. Operator radiation exposure was analyzed according to the position of the patient right arm (close or far from the body) and in relation to the size of the upper leaded glass.

RESULTS

Among the 14 operators who agreed to participate, there was a greater than 10-fold difference in radiation dose at thorax level (from 21.5 to 267 μSv) that persisted after normalization by dose-area product (from 0.35 to 3.5 μSv/Gy*cm). Among the operators who positioned the instrumented right arm far from the body (110.4 μSv, interquartile range 71.5-146.5 μSv), thorax dose was greater than that in those who placed the instrumented arm close to the right leg (46.1 μSv, 31.3-56.8 μSv, P = .02). This difference persisted after normalization by dose-area product (P = .028). The use of a smaller full glass shield was also associated with a higher radiation exposure compared with a larger composite shield (147.5 and 60 μSv, respectively, P = .016).

CONCLUSIONS

In the context of the biggest radiation study conducted in patients undergoing transradial catheterization, the instrumented right arm arrangement close to the leg and greater upper leaded shield dimensions were associated with a lower operator radiation exposure. Our findings emphasize the importance of implementing simple preventive measures to mitigate the extra risks of radiation exposure with right radial as compared with femoral access.
Date of Publication
2018-02
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
300 Social sciences, sociology & anthropology > 360 Social problems & social services
Language(s)
en
Contributor(s)
Sciahbasi, Alessandro
Frigoli, Enrico
Sarandrea, Alessandro
Calabrò, Paolo
Rubartelli, Paolo
Cortese, Bernardo
Tomassini, Francesco
Zavalloni, Dennis
Tebaldi, Matteo
Calabria, Paolo
Rigattieri, Stefano
Zingarelli, Antonio
Sardella, Gennaro
Lupi, Alessandro
Rothenbühler, Martinaorcid-logo
Clinical Trials Unit Bern (CTU)
Institut für Sozial- und Präventivmedizin (ISPM)
Heg, Dierik Hansorcid-logo
Clinical Trials Unit Bern (CTU)
Institut für Sozial- und Präventivmedizin (ISPM)
Valgimigli, Marco
Universitätsklinik für Kardiologie
Additional Credits
Clinical Trials Unit Bern (CTU)
Universitätsklinik für Kardiologie
Series
American Heart Journal
Publisher
Elsevier
ISSN
0002-8703
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo