INTRODUCTION

Measuring factor VIII (FVIII) activity can be challenging when it has been modified, such as when FVIII is pegylated to increase its circulating half-life. Use of a product-specific reference standard may help avoid this issue.

AIM

Evaluate the impact of using a product-specific reference standard for measuring the FVIII activity of BAX 855 - a pegylated FVIII - in eight of Switzerland's main laboratories.

METHODS

Factor VIII-deficient plasma, spiked with five different concentrations of BAX 855, plus a control FVIII sample, was sent to the participating laboratories. They measured FVIII activity by using either with a one-stage (OSA) or the chromogenic assay (CA) against their local or a product-specific reference standard.

RESULTS

When using a local reference standard, there was an overestimation of BAX 855 activity compared to the target concentrations, both with the OSA and CA. The use of a product-specific reference standard reduced this effect: mean recovery ranged from 127.7% to 213.5% using the OSA with local reference standards, compared to 110% to 183.8% with a product-specific reference standard, and from 146.3% to 182.4% using the CA with local reference standards compared to 72.7% to 103.7% with a product-specific reference standard.

CONCLUSION

In this in vitro study, the type of reference standard had a major impact on the measurement of BAX 855 activity. Evaluation was more accurate and precise when using a product-specific reference standard.
Date of Publication
2017-07
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
in vitro blood coagulation blood coagulation tests drug monitoring factor VIII procoagulant activity haemophilia A
Language(s)
en
Contributor(s)
Bulla, O
Poncet, A
Alberio, L
Asmis, L M
Gähler, A
Graf, L
Nagler, Michael
Department for BioMedical Research, Forschungsgruppe Hämatologie (Erwachsene)
Universitätsklinik für Hämatologie und Hämatologisches Zentrallabor
Studt, J-D
Tsakiris, D A
Fontana, P
Additional Credits
Department for BioMedical Research, Forschungsgruppe Hämatologie (Erwachsene)
Series
Haemophilia
Publisher
Wiley
ISSN
1351-8216
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo