• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. 3D morphometry using automated aortic segmentation in native MR angiography: an alternative to contrast enhanced MRA?

3D morphometry using automated aortic segmentation in native MR angiography: an alternative to contrast enhanced MRA?

Details
Files
DOI
10.7892/boris.66784
Publisher DOI
10.3978/j.issn.2223-3652.2013.10.06
PubMed ID
24834406
Abstract
INTRODUCTION

Native-MR angiography (N-MRA) is considered an imaging alternative to contrast enhanced MR angiography (CE-MRA) for patients with renal insufficiency. Lower intraluminal contrast in N-MRA often leads to failure of the segmentation process in commercial algorithms. This study introduces an in-house 3D model-based segmentation approach used to compare both sequences by automatic 3D lumen segmentation, allowing for evaluation of differences of aortic lumen diameters as well as differences in length comparing both acquisition techniques at every possible location.

METHODS AND MATERIALS

Sixteen healthy volunteers underwent 1.5-T-MR Angiography (MRA). For each volunteer, two different MR sequences were performed, CE-MRA: gradient echo Turbo FLASH sequence and N-MRA: respiratory-and-cardiac-gated, T2-weighted 3D SSFP. Datasets were segmented using a 3D model-based ellipse-fitting approach with a single seed point placed manually above the celiac trunk. The segmented volumes were manually cropped from left subclavian artery to celiac trunk to avoid error due to side branches. Diameters, volumes and centerline length were computed for intraindividual comparison. For statistical analysis the Wilcoxon-Signed-Ranked-Test was used.

RESULTS

Average centerline length obtained based on N-MRA was 239.0±23.4 mm compared to 238.6±23.5 mm for CE-MRA without significant difference (P=0.877). Average maximum diameter obtained based on N-MRA was 25.7±3.3 mm compared to 24.1±3.2 mm for CE-MRA (P<0.001). In agreement with the difference in diameters, volumes obtained based on N-MRA (100.1±35.4 cm(3)) were consistently and significantly larger compared to CE-MRA (89.2±30.0 cm(3)) (P<0.001).

CONCLUSIONS

3D morphometry shows highly similar centerline lengths for N-MRA and CE-MRA, but systematically higher diameters and volumes for N-MRA.
Date Issued
2014-04
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Magnetic resonance angiography
•
aorta
•
automatic data processing
•
thoracic
Language(s)
en
Author(s)
Müller-Eschner, Matthias
Müller, Tobias
Biesdorf, Andreas
Wörz, Stefan
Rengier, Fabian
Böckler, Dittmar
Kauczor, Hans-Ulrich
Rohr, Karl
von Tengg-Kobligk, Hendrik  
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie  
Additional Credits
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie  
Journal
Cardiovascular diagnosis and therapy
Publisher
AME Publishing Company
ISSN
2223-3652
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify