Publication:
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies

cris.virtualsource.author-orcidce530ca4-1774-40f4-b3ef-33508afa7352
dc.contributor.authorWhiting, Penny F
dc.contributor.authorRutjes, Anne
dc.contributor.authorWestwood, Marie E
dc.contributor.authorMallett, Susan
dc.contributor.authorDeeks, Jonathan J
dc.contributor.authorReitsma, Johannes B
dc.contributor.authorLeeflang, Mariska M G
dc.contributor.authorSterne, Jonathan A C
dc.contributor.authorBossuyt, Patrick M M
dc.date.accessioned2024-10-11T09:25:08Z
dc.date.available2024-10-11T09:25:08Z
dc.date.issued2011
dc.description.abstractIn 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
dc.description.numberOfPages8
dc.description.sponsorshipInstitut für Sozial- und Präventivmedizin (ISPM)
dc.identifier.doi10.7892/boris.7590
dc.identifier.isi000296066300018
dc.identifier.pmid22007046
dc.identifier.publisherDOI10.1059/0003-4819-155-8-201110180-00009
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/78041
dc.language.isoen
dc.publisherAmerican College of Physicians
dc.publisher.placePhiladelphia, Pa.
dc.relation.ispartofAnnals of internal medicine
dc.relation.issn0003-4819
dc.relation.organizationDCD5A442BECFE17DE0405C82790C4DE2
dc.titleQUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage536
oaire.citation.issue8
oaire.citation.startPage529
oaire.citation.volume155
oairecerif.author.affiliationInstitut für Sozial- und Präventivmedizin (ISPM)
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2017-09-10 06:54:33
unibe.description.ispublishedpub
unibe.eprints.legacyId7590
unibe.journal.abbrevTitleANN INTERN MED
unibe.refereedTRUE
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Whiting AnnInternMed 2011.pdf
Size:
146.4 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections