• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Accuracy of navigated surgery of the pelvis after surface matching with an a-mode ultrasound probe
 

Accuracy of navigated surgery of the pelvis after surface matching with an a-mode ultrasound probe

Options
  • Details
Publisher DOI
10.1002/jor.20551
PubMed ID
18240332
Description
Computer-aided surgery (CAS) allows for real-time intraoperative feedback resulting in increased accuracy, while reducing intraoperative radiation. CAS is especially useful for the treatment of certain pelvic ring fractures, which necessitate the precise placement of screws. Flouroscopy-based CAS modules have been developed for many orthopedic applications. The integration of the isocentric flouroscope even enables navigation using intraoperatively acquired three-dimensional (3D) data, though the scan volume and imaging quality are limited. Complicated and comprehensive pathologies in regions like the pelvis can necessitate a CT-based navigation system because of its larger field of view. To be accurate, the patient's anatomy must be registered and matched with the virtual object (CT data). The actual precision within the region of interest depends on the area of the bone where surface matching is performed. Conventional surface matching with a solid pointer requires extensive soft tissue dissection. This contradicts the primary purpose of CAS as a minimally invasive alternative to conventional surgical techniques. We therefore integrated an a-mode ultrasound pointer into the process of surface matching for pelvic surgery and compared it to the conventional method. Accuracy measurements were made in two pelvic models: a foam model submerged in water and one with attached porcine muscle tissue. Three different tissue depths were selected based on CT scans of 30 human pelves. The ultrasound pointer allowed for registration of virtually any point on the pelvis. This method of surface matching could be successfully integrated into CAS of the pelvis.
Date of Publication
2008
Publication Type
Article
Language(s)
en
Contributor(s)
Oszwald, M
Citak, M
Kendoff, D
Kowal, Horst Jens
Institut für chirurgische Technologien und Biomechanik (ISTB)
Amstutz, Christoph Andreas
Universitätsklinik für Augenheilkunde
Kirchhoff, T
Nolte, Lutz-Peter
Institut für chirurgische Technologien und Biomechanik (ISTB)
Krettek, C
Hüfner, T
Additional Credits
Institut für chirurgische Technologien und Biomechanik (ISTB)
Universitätsklinik für Augenheilkunde
Series
Journal of orthopaedic research
Publisher
Wiley
ISSN
0736-0266
ISBN
18240332
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo