• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Long-Term Durability of Transcatheter Aortic Valves in Patients With Bicuspid Aortic Stenosis.
 

Long-Term Durability of Transcatheter Aortic Valves in Patients With Bicuspid Aortic Stenosis.

Options
  • Details
  • Files
BORIS DOI
10.48620/89050
Publisher DOI
10.1002/ccd.31742
PubMed ID
40611498
Description
Background
Data concerning the long-term durability of transcatheter aortic valves (TAVs) in patients with bicuspid aortic stenosis (AS) are lacking.
Aims
The study aims to report data on long-term valve durability following transcatheter aortic valve replacement (TAVR) in bicuspid AS.
Methods
This multicentre registry included patients who underwent TAVR for bicuspid AS with at least 2-year echocardiographic follow-up. The incidence of structural valve deterioration (SVD), bioprosthetic valve dysfunction (BVD), and bioprosthetic valve failure (BVF) was determined according to Valve Academic Research Consortium (VARC)-3 criteria.
Results
Among 894 patients (mean age: 75.6 years; 39% female), the median echocardiographic follow-up was 48.7 months with a 5-year cumulative incidence of moderate-to-severe SVD, severe SVD, severe BVD, and BVF of 8.1%, 3.2%, 11.4%, and 6.1%, respectively. Younger age (≤ 75 years) was associated with a higher likelihood of reintervention (HR 2.40, log-rank p = 0.04). TAV downsizing was associated with higher rates of moderate-to-severe SVD (HR 3.05, log-rank p < 0.001), severe BVD (HR 2.07, log-rank p = 0.003), and BVF (HR 3.25, log-rank p = 0.002). In the sub-group with small annuli (area ≤ 430 mm2), implantation of balloon-expandable TAVs was associated with a higher rate of BVD in comparison with self-expanding TAVs (HR: 3.27, log-rank p = 0.008).
Conclusions
TAVs demonstrated favorable 5-year durability in patients with bicuspid AS, although younger patients were more likely to require valve reintervention. Nominal TAV sizing was associated with better durability outcomes as compared to TAV downsizing. Self-expanding valves were associated with superior hemodynamics in patients with small annuli.
Date of Publication
2025-09
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
aortic stenosis
•
bicuspid aortic valve
•
transcatheter aortic valve replacement
•
valve durability
Language(s)
en
Contributor(s)
Jia, Yuheng
Maznyczka, Annette
Boiago, Mauro
Khokhar, Arif
Tomii, Daijiro
Clinic of Cardiology
Neylon, Antoinette
Danthine, Pauline
Levesque, Thomas
Bamford, Paul
Toggweiler, Stefan
Moccetti, Federico
Piuhola, Jarkko
Adamo, Marianna
Massussi, Mauro
Lelasi, Alfonso
Montorfano, Matteo
Costa, Giulia
Swaans, Martin
Overduin, Daniël C
Servoz, Clément
Gandolfo, Caterina
Guðmundsdóttir, Ingibjörg Jóna
Salizzoni, Stefano
Wykrzykowska, Joanna J
van Bergeijk, Kees H
Buono, Andrea
Hartikainen, Tau
Noble, Stephane
Mylotte, Darren
Brecker, Stephen
Thabit, Ahmed
Mangieri, Antonio
Agostoni, Pierfrancesco
Bunc, Matjaž
Vanhaverbeke, Maarten
Bosmans, Johan
Eltchaninoff, Hélène
Latib, Azeem
Blackman, Daniel
Van Mieghem, Nicolas M
Feng, Yuan
Kim, Won-Keun
Pilgrim, Thomas
Clinic of Cardiology
Prendergast, Bernard
Tchétché, Didier
Chen, Mao
De Backer, Ole
Additional Credits
Clinic of Cardiology
Series
Catheterization & Cardiovascular Interventions
Publisher
Wiley
ISSN
1522-726X
1522-1946
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo