  3. Diagnostic confidence and image quality of CT pulmonary angiography at 100 kVp in overweight and obese patients.
 

Diagnostic confidence and image quality of CT pulmonary angiography at 100 kVp in overweight and obese patients.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.66795
Publisher DOI
10.1016/j.crad.2014.09.014
PubMed ID
25459197
Description
AIM

To compare image quality and diagnostic confidence of 100 kVp CT pulmonary angiography (CTPA) in patients with body weights (BWs) below and above 100kg.

MATERIALS AND METHODS

The present retrospective study comprised 216 patients (BWs of 75-99kg, 114 patients; 100-125kg, 88 patients; >125kg, 14 patients), who received 100 kVp CTPA to exclude pulmonary embolism. The attenuation was measured and the contrast-to-noise ratio (CNR) was calculated in the pulmonary trunk. Size-specific dose estimates (SSDEs) were evaluated. Three blinded radiologists rated subjective image quality and diagnostic confidence. Results between the BW groups and between three body mass index (BMI) groups (BMI <25kg/m(2), BMI = 25-29.9kg/m(2), and BMI ≥30kg/m(2), i.e., normal weight, overweight, and obese patients) were compared using the Kruskal-Wallis test.

RESULTS

Vessel attenuation was higher and SDDE was lower in the 75-99kg group than at higher BWs (p-values between <0.001 and 0.03), with no difference between the 100-125 and >125kg groups (p = 0.892 and 1). Subjective image quality and diagnostic confidence were not different among the BW groups (p = 0.225 and 1). CNR was lower (p < 0.006) in obese patients than in normal weight or overweight subjects. Diagnostic confidence was not different in the BMI groups (p = 0.105).

CONCLUSION

CTPA at 100 kVp tube voltage can be used in patients weighing up to 125kg with no significant deterioration of subjective image quality and confidence. The applicability of 100 kVp in the 125-150kg BW range needs further testing in larger collectives.
Date of Publication
2015-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Megyeri, B
Christe, Andreas
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
Schindera, S T
Horkay, E
Sikula, J
Cullmann, J L
Kollar, J
Heverhagen, J T
Szucs-Farkas, Z
Additional Credits
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
Series
Clinical radiology
Publisher
Elsevier Science
ISSN
0009-9260
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo