  2. Publications
  3. Manual Electrode Array Insertion Through a Robot-assisted Minimal Invasive Cochleostomy: Feasibility and Comparison of Two Different Electrode Array Subtypes.
 

Manual Electrode Array Insertion Through a Robot-assisted Minimal Invasive Cochleostomy: Feasibility and Comparison of Two Different Electrode Array Subtypes.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.69270
Publisher DOI
10.1097/MAO.0000000000000741
PubMed ID
25853609
Description
HYPOTHESIS

To evaluate the feasibility and the results of insertion of two types of electrode arrays in a robotically assisted surgical approach.

BACKGROUND

Recent publications demonstrated that robot-assisted surgery allows the implantation of free-fitting electrode arrays through a cochleostomy drilled via a narrow bony tunnel (DCA). We investigated if electrode arrays from different manufacturers could be used with this approach.

METHODS

Cone-beam CT imaging was performed on fivecadaveric heads after placement of fiducial screws. Relevant anatomical structures were segmented and the DCA trajectory, including the position of the cochleostomy, was defined to target the center of the scala tympani while reducing the risk of lesions to the facial nerve. Med-El Flex 28 and Cochlear CI422 electrodes were implanted on both sides, and their position was verified by cone-beam CT. Finally, temporal bones were dissected to assess the occurrence of damage to anatomical structures during DCA drilling.

RESULTS

The cochleostomy site was directed in the scala tympani in 9 of 10 cases. The insertion of electrode arrays was successful in 19 of 20 attempts. No facial nerve damage was observed. The average difference between the planned and the postoperative trajectory was 0.17 ± 0.19 mm at the level of the facial nerve. The average depth of insertion was 305.5 ± 55.2 and 243 ± 32.1 degrees with Med-El and Cochlear arrays, respectively.

CONCLUSIONS

Robot-assisted surgery is a reliable tool to allow cochlear implantation through a cochleostomy. Technical solutions must be developed to improve the electrode array insertion using this approach.
Date of Publication
2015-04-07
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Venail, Frederic
Bell, Brett
ARTORG Center - Image Guided Therapy
Akkari, Mohamed
Wimmer, Wilhelmorcid-logo
ARTORG Center - Hearing Research Laboratory
Williamson, Tom
ARTORG Center - Image Guided Therapy
Gerber, Nicolasorcid-logo
ARTORG Center - Hearing Research Laboratory
Gerber, Kateorcid-logo
ARTORG Center - Image Guided Therapy
Canovas, Francois
Weber, Stefan
ARTORG Center - Image Guided Therapy
Caversaccio, Marco
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
ARTORG Center - Hearing Research Laboratory
Uziel, Alain
Additional Credits
ARTORG Center - Image Guided Therapy
ARTORG Center - Hearing Research Laboratory
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
Series
Otology & neurotology
Publisher
Lippincott Williams & Wilkins
ISSN
1531-7129
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo