  3. Reliability of a two-colour chewing gum test to assess masticatory performance in complete denture wearers.
 

Reliability of a two-colour chewing gum test to assess masticatory performance in complete denture wearers.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.123994
Publisher DOI
10.1111/joor.12609
PubMed ID
29356092
Description
The aim of this study was to test the reliability of a method to measure the masticatory performance of complete denture wearers employing a colour-mixing ability test and assessment by visual and electronic colourimetric analysis. A sample of 75 subjects was selected from patients who received new conventional complete dentures. Masticatory tests were performed using a two-colour chewing gum that was masticated for 5, 10, 20, 30 and 50 chewing cycles, performed in a random order. The mixing level of the two colours of the chewed gum was assessed visually by two independent raters based on a 5-point ordinal scale. The specimens were flattened into a 1-mm-width wafer, scanned and saved as a two-sided digital image. Each pair of images was submitted to an electronic colourimetric analysis to assess the level of colour mixture, measured by the circular variance of hue (VOH). Overall inter- and intra-rater agreements in visual analysis were 64% and 68%, respectively (almost 99% of scores ranged within ±1 point), whilst overall weighted kappa was >0.80. A proportional increase in the level of mixture occurred with increased number of chewing cycles (P < .001). Similarly, VOH and the visual analysis were highly correlated (r = -.89; P < .001). Bland-Altman plots revealed excellent agreement and extremely low systematic error between duplicated VOH measures. It was concluded that the two-colour chewing gum test is a reliable method to assess the masticatory performance in complete denture wearers using both visual and electronic colourimetric analyses.
Date of Publication
2018-04
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
clinical research complete denture edentulous patients electronic analysis masticatory performance reliability
Language(s)
en
Contributor(s)
Silva, L C
Nogueira, T E
Rios, L F
Schimmel, Martinorcid-logo
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Leles, C R
Additional Credits
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Series
Journal of oral rehabilitation
Publisher
Blackwell Scientific Publications
ISSN
0305-182X
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo