  3. Screening for lupus anticoagulant: improving the performance of the lupus-sensitive PTT-LA
 

Screening for lupus anticoagulant: improving the performance of the lupus-sensitive PTT-LA

Options
  • Details
Publisher DOI
10.1111/j.1751-553X.2010.01262.x
PubMed ID
20860735
Description
Introduction: The aim of the present work was to verify whether calculating a ratio between clotting times obtained with the sensitive PTT-LA and a less sensitive activated partial thromboplastin time (aPTT)-reagent may represent a valuable aPTT-based screening strategy for lupus anticoagulants (LA). Methods: For the pilot study, plasma samples from normal subjects (n = 15) and from patients with LA (n = 10), therapeutic anticoagulation with vitamin K-antagonists (VKA) (n = 15) or unfractionated heparin (n = 15), coagulation factors deficiency (n = 16), and inhibitory antibodies against factor VIII or IX (n = 11) were studied. For the evaluation study, 1553 consecutive plasma samples from nonanticoagulated patients investigated for LA between January 2005 and December 2007 at our institution were studied. Following screening strategies were employed: Pathromtin-SL (aPTT-SL), PTT-LA (aPTT-LA), ratio aPTT-LA/aPTT-SL (aPTT-ratio), and Russell's viper venom (RVV) based LA-Check. LA positive samples were identified by mixing studies and diluted RVV confirmation test (LA-Check/LA-Sure). Results: Pilot study: All screening strategies had a 100% sensitivity, and the aPTT-ratio reached the highest specificity (82%; 95%CI: 74-90%). Within the evaluation study, following sensitivities for LA screening were observed: aPTT-SL 59.0% (95%CI: 57-61%), aPTT-LA 82.1% (95%CI: 80-84%), aPTT-ratio 92.3% (95%CI: 91-94), and LA-Check 83.3% (95%CI: 82-85%). Conclusion: Calculating a ratio between the LA-sensitive PTT-LA and the less sensitive Pathromtin-SL improves the performance of the PTT-LA itself and represents a simple and sensitive aPTT-based integrated strategy for LA screening.
Date of Publication
2010
Publication Type
Article
Language(s)
en
Contributor(s)
Luginbühl, R
Barizzi, G
Sulzer, I
Lämmle, Bernhard
Universitätsklinik für Hämatologie und Hämatologisches Zentrallabor
Alberio, Lorenzo
Universitätsklinik für Hämatologie und Hämatologisches Zentrallabor
Additional Credits
Universitätsklinik für Hämatologie und Hämatologisches Zentrallabor
Series
International journal of laboratory hematology
Publisher
Blackwell Scientific Publications
ISSN
1751-5521
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo