Publication:
Simultaneous multiple breath washout and oxygen-enhanced magnetic resonance imaging in healthy adults.

cris.virtual.author-orcid0000-0003-1140-9437
cris.virtual.author-orcid0000-0002-5239-1571
cris.virtualsource.author-orcide655a41d-a5d1-46d1-917c-f4bab69a2c9d
cris.virtualsource.author-orcid8800e3e0-f6c7-40e3-be32-e0c4aa496407
cris.virtualsource.author-orcidc78a191b-4014-4c0e-9c6f-c43327df9b50
cris.virtualsource.author-orcid7457a40a-9226-489a-9650-a936c14fb53f
cris.virtualsource.author-orcid7eb6a680-ff77-43fa-8ca2-9ad29a2a1780
datacite.rightsopen.access
dc.contributor.authorKentgens, Anne-Christianne
dc.contributor.authorPusterla, Orso
dc.contributor.authorBauman, Grzegorz
dc.contributor.authorSantini, Francesco
dc.contributor.authorWyler, Florian
dc.contributor.authorCurdy, Marion S
dc.contributor.authorWillers, Christoph Corin
dc.contributor.authorBieri, Oliver
dc.contributor.authorLatzin, Philipp
dc.contributor.authorRamsey, Kathryn Angela
dc.date.accessioned2024-10-25T16:17:47Z
dc.date.available2024-10-25T16:17:47Z
dc.date.issued2023-06
dc.description.abstractLung function testing and lung imaging are commonly used techniques to monitor respiratory diseases, such as cystic fibrosis (CF). The nitrogen (N2) multiple-breath washout technique (MBW) has been shown to detect ventilation inhomogeneity in CF, but the underlying pathophysiological processes that are altered are often unclear. Dynamic oxygen-enhanced magnetic resonance imaging (OE-MRI) could potentially be performed simultaneously with MBW because both techniques require breathing of 100% oxygen (O2) and may allow for visualisation of alterations underlying impaired MBW outcomes. However, simultaneous MBW and OE-MRI has never been assessed, potentially as it requires a magnetic resonance (MR) compatible MBW equipment. In this pilot study, we assessed whether MBW and OE-MRI can be performed simultaneously using a commercial MBW device that has been modified to be MR-compatible. We performed simultaneous measurements in five healthy volunteers aged 25-35 years. We obtained O2 and N2 concentrations from both techniques, and generated O2 wash-in time constant and N2 washout maps from OE-MRI data. We obtained good quality simultaneous measurements in two healthy volunteers due to technical challenges related to the MBW equipment and poor tolerance. Oxygen and N2 concentrations from both techniques, as well as O2 wash-in time constant maps and N2 washout maps could be obtained, suggesting that simultaneous measurements may have the potential to allow for comparison and visualization of regional differences in ventilation underlying impaired MBW outcomes. Simultaneous MBW and OE-MRI measurements can be performed with a modified MBW device and may help to understand MBW outcomes, but the measurements are challenging and have poor feasibility.
dc.description.sponsorshipUniversitätsklinik für Kinderheilkunde
dc.description.sponsorshipUniversitätsklinik für Kinderheilkunde - Pneumologie / Allergologie
dc.identifier.doi10.48350/181742
dc.identifier.pmid37058881
dc.identifier.publisherDOI10.1016/j.resmer.2023.100993
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/166478
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofRespiratory medicine and research
dc.relation.issn2590-0412
dc.relation.organizationDepartment of Paediatrics
dc.relation.organizationClinic of Paediatric Medicine, Paediatric Pneumology
dc.relation.schoolGraduate School for Health Sciences (GHS)
dc.subjectCystic fibrosis Diagnostics Lung function Lung imaging Ventilation inhomogeneity oxygen-enhanced MRI
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleSimultaneous multiple breath washout and oxygen-enhanced magnetic resonance imaging in healthy adults.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.issue100993
oaire.citation.startPage100993
oaire.citation.volume83
oairecerif.author.affiliationUniversitätsklinik für Kinderheilkunde
oairecerif.author.affiliationUniversitätsklinik für Kinderheilkunde
oairecerif.author.affiliationUniversitätsklinik für Kinderheilkunde
oairecerif.author.affiliationUniversitätsklinik für Kinderheilkunde - Pneumologie / Allergologie
oairecerif.author.affiliationUniversitätsklinik für Kinderheilkunde
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2023-04-18 06:28:06
unibe.description.ispublishedpub
unibe.eprints.legacyId181742
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
1-s2.0-S2590041223000053-main.pdf
Size:
1.28 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by-nc-nd/4.0
Content:
published

Collections