Publication:
Balloon-assisted coil embolization and large stent delivery for cerebral aneurysms with a new generation of dual lumen balloons (Copernic 2L).

cris.virtualsource.author-orcidc99f0a86-49c9-440f-89f8-e0aed79798b0
cris.virtualsource.author-orcided94684c-aab2-4a33-92f7-e9f033655dd3
cris.virtualsource.author-orcid29e771f2-4628-4190-b532-748410b5aff5
cris.virtualsource.author-orcid6bca269a-b080-43cf-a340-2559fc2f7595
cris.virtualsource.author-orcid6cad49b2-8963-4468-b104-ea5b331577f8
cris.virtualsource.author-orcid5f32c389-197d-4c15-84f4-4f8da48f6fff
datacite.rightsrestricted
dc.contributor.authorGuenego, Adrien
dc.contributor.authorZerlauth, Jean-Baptiste
dc.contributor.authorPuccinelli, Francesco
dc.contributor.authorHajdu, Steven
dc.contributor.authorRotzinger, David C
dc.contributor.authorZibold, Felix
dc.contributor.authorPiechowiak, Eike Immo
dc.contributor.authorMordasini, Pasquale Renato
dc.contributor.authorGralla, Jan
dc.contributor.authorDobrocky, Tomas
dc.contributor.authorDaniel, Roy T
dc.contributor.authorChapot, René
dc.contributor.authorMosimann, Pascal John
dc.date.accessioned2024-10-25T06:11:14Z
dc.date.available2024-10-25T06:11:14Z
dc.date.issued2018-04
dc.description.abstractINTRODUCTION Dual coaxial lumen balloon microcatheters through which small stents can be delivered have recently been described. We report a series of a new type of dual lumen balloon catheter with a parallel lumen design enabling enhanced inflation and deflation properties through which larger stents may be deployed, including flow diverters (FD). METHODS All aneurysms that were treated with a Copernic 2L (COP2L) dual lumen balloon catheter at our institution between February 2014 and December 2016 were assessed. Patient demographics, aneurysm characteristics, clinical and angiographic follow-up, as well as adverse events were analyzed. RESULTS A total of 18 aneurysms in 16 patients (14 women) were treated with the COP2L. Mean maximal aneurysm diameter was 6.4 mm, mean neck size was 3.3 mm (min 1; max 6.3), and mean aneurysm height/width was 1.1 (min 0.5; max 2.1). The COP2L was used for balloon-remodeled coiling exclusively in 2 aneurysms; coiling and FD stenting in 8; coiling and braided stent delivery in 3; coiling, braided and FD stenting in 1; and FD stenting without coiling in 4 (stenting alone). The rate of Roy-Raymond 1 (complete occlusion) changed from 22% in the immediate postoperative period to 100% at 3 months (mean imaging follow-up 8.2 months). There were three technical complications (3/16, 18.7%), including a perforation and two thromboembolic asymptomatic events that were rapidly controlled with the COP2L. There was no immediate or delayed morbidity or mortality (modified Rankin Scale score 0-1 in 100% of patients). CONCLUSION The COP2L is a new type of dual lumen balloon catheter that may be useful for balloon and/or stent-assisted coiling of cerebral aneurysms. The same device can be used to deliver stents up to 4.5 mm and to optimize stent/wall apposition or serve as a life-saving tool in case of thromboembolic or hemorrhagic events. Long-term efficacy and safety need to be further assessed with larger case-controlled cohorts.
dc.description.numberOfPages6
dc.description.sponsorshipUniversitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
dc.identifier.doi10.7892/boris.102472
dc.identifier.pmid28754807
dc.identifier.publisherDOI10.1136/neurintsurg-2017-013218
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/154096
dc.language.isoen
dc.publisherBMJ Publishing Group
dc.relation.ispartofJournal of neurointerventional surgery
dc.relation.issn1759-8486
dc.relation.organizationDCD5A442C011E17DE0405C82790C4DE2
dc.subjectaneurysms dual lumen balloon embolization large stent delivery onyx
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleBalloon-assisted coil embolization and large stent delivery for cerebral aneurysms with a new generation of dual lumen balloons (Copernic 2L).
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage400
oaire.citation.issue4
oaire.citation.startPage395
oaire.citation.volume10
oairecerif.author.affiliationUniversitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
oairecerif.author.affiliationUniversitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
oairecerif.author.affiliationUniversitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
oairecerif.author.affiliationUniversitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
oairecerif.author.affiliationUniversitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
oairecerif.author.affiliationUniversitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2017-10-30 10:27:34
unibe.description.ispublishedpub
unibe.eprints.legacyId102472
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
neurintsurg-2017-013218.full.pdf
Size:
861.55 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections