Publication: Balloon-assisted coil embolization and large stent delivery for cerebral aneurysms with a new generation of dual lumen balloons (Copernic 2L).
cris.virtualsource.author-orcid | c99f0a86-49c9-440f-89f8-e0aed79798b0 | |
cris.virtualsource.author-orcid | ed94684c-aab2-4a33-92f7-e9f033655dd3 | |
cris.virtualsource.author-orcid | 29e771f2-4628-4190-b532-748410b5aff5 | |
cris.virtualsource.author-orcid | 6bca269a-b080-43cf-a340-2559fc2f7595 | |
cris.virtualsource.author-orcid | 6cad49b2-8963-4468-b104-ea5b331577f8 | |
cris.virtualsource.author-orcid | 5f32c389-197d-4c15-84f4-4f8da48f6fff | |
datacite.rights | restricted | |
dc.contributor.author | Guenego, Adrien | |
dc.contributor.author | Zerlauth, Jean-Baptiste | |
dc.contributor.author | Puccinelli, Francesco | |
dc.contributor.author | Hajdu, Steven | |
dc.contributor.author | Rotzinger, David C | |
dc.contributor.author | Zibold, Felix | |
dc.contributor.author | Piechowiak, Eike Immo | |
dc.contributor.author | Mordasini, Pasquale Renato | |
dc.contributor.author | Gralla, Jan | |
dc.contributor.author | Dobrocky, Tomas | |
dc.contributor.author | Daniel, Roy T | |
dc.contributor.author | Chapot, René | |
dc.contributor.author | Mosimann, Pascal John | |
dc.date.accessioned | 2024-10-25T06:11:14Z | |
dc.date.available | 2024-10-25T06:11:14Z | |
dc.date.issued | 2018-04 | |
dc.description.abstract | INTRODUCTION Dual coaxial lumen balloon microcatheters through which small stents can be delivered have recently been described. We report a series of a new type of dual lumen balloon catheter with a parallel lumen design enabling enhanced inflation and deflation properties through which larger stents may be deployed, including flow diverters (FD). METHODS All aneurysms that were treated with a Copernic 2L (COP2L) dual lumen balloon catheter at our institution between February 2014 and December 2016 were assessed. Patient demographics, aneurysm characteristics, clinical and angiographic follow-up, as well as adverse events were analyzed. RESULTS A total of 18 aneurysms in 16 patients (14 women) were treated with the COP2L. Mean maximal aneurysm diameter was 6.4 mm, mean neck size was 3.3 mm (min 1; max 6.3), and mean aneurysm height/width was 1.1 (min 0.5; max 2.1). The COP2L was used for balloon-remodeled coiling exclusively in 2 aneurysms; coiling and FD stenting in 8; coiling and braided stent delivery in 3; coiling, braided and FD stenting in 1; and FD stenting without coiling in 4 (stenting alone). The rate of Roy-Raymond 1 (complete occlusion) changed from 22% in the immediate postoperative period to 100% at 3 months (mean imaging follow-up 8.2 months). There were three technical complications (3/16, 18.7%), including a perforation and two thromboembolic asymptomatic events that were rapidly controlled with the COP2L. There was no immediate or delayed morbidity or mortality (modified Rankin Scale score 0-1 in 100% of patients). CONCLUSION The COP2L is a new type of dual lumen balloon catheter that may be useful for balloon and/or stent-assisted coiling of cerebral aneurysms. The same device can be used to deliver stents up to 4.5 mm and to optimize stent/wall apposition or serve as a life-saving tool in case of thromboembolic or hemorrhagic events. Long-term efficacy and safety need to be further assessed with larger case-controlled cohorts. | |
dc.description.numberOfPages | 6 | |
dc.description.sponsorship | Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie | |
dc.identifier.doi | 10.7892/boris.102472 | |
dc.identifier.pmid | 28754807 | |
dc.identifier.publisherDOI | 10.1136/neurintsurg-2017-013218 | |
dc.identifier.uri | https://boris-portal.unibe.ch/handle/20.500.12422/154096 | |
dc.language.iso | en | |
dc.publisher | BMJ Publishing Group | |
dc.relation.ispartof | Journal of neurointerventional surgery | |
dc.relation.issn | 1759-8486 | |
dc.relation.organization | DCD5A442C011E17DE0405C82790C4DE2 | |
dc.subject | aneurysms dual lumen balloon embolization large stent delivery onyx | |
dc.subject.ddc | 600 - Technology::610 - Medicine & health | |
dc.title | Balloon-assisted coil embolization and large stent delivery for cerebral aneurysms with a new generation of dual lumen balloons (Copernic 2L). | |
dc.type | article | |
dspace.entity.type | Publication | |
dspace.file.type | text | |
oaire.citation.endPage | 400 | |
oaire.citation.issue | 4 | |
oaire.citation.startPage | 395 | |
oaire.citation.volume | 10 | |
oairecerif.author.affiliation | Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie | |
oairecerif.author.affiliation | Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie | |
oairecerif.author.affiliation | Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie | |
oairecerif.author.affiliation | Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie | |
oairecerif.author.affiliation | Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie | |
oairecerif.author.affiliation | Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.date.licenseChanged | 2017-10-30 10:27:34 | |
unibe.description.ispublished | pub | |
unibe.eprints.legacyId | 102472 | |
unibe.refereed | true | |