Publication: Cutting-edge microangio-CT: new dimensions in vascular imaging and kidney morphometry.
cris.virtual.author-orcid | 0000-0001-7049-856X | |
cris.virtual.author-orcid | 0000-0003-3880-4437 | |
cris.virtual.author-orcid | 0000-0002-5062-1169 | |
cris.virtualsource.author-orcid | 6b9f7e28-8a66-49ee-abac-5a92d89b810b | |
cris.virtualsource.author-orcid | 497be4b9-a901-4bab-9df2-c7731c8fdd20 | |
cris.virtualsource.author-orcid | 2f94d207-f798-4c8e-9906-ce88d3f15c2d | |
cris.virtualsource.author-orcid | 186ae18e-3904-4a62-b7ea-502edd29f3bb | |
cris.virtualsource.author-orcid | 103af363-413d-4cc3-b488-1ce4a59686be | |
cris.virtualsource.author-orcid | 88fd6986-8645-46a3-bbfa-b3ed9a5dd57e | |
cris.virtualsource.author-orcid | c820db14-6b41-459c-a424-2cdf0cc45377 | |
cris.virtualsource.author-orcid | aeba9e0a-b3a9-4d7a-8207-e34ae1262581 | |
cris.virtualsource.author-orcid | 906070e9-5f44-4fcf-b26c-5e36f8e66f58 | |
cris.virtualsource.author-orcid | 50f55964-7ff8-4bc0-8549-9919a3cbee93 | |
dc.contributor.author | Hlushchuk, Ruslan | |
dc.contributor.author | Zubler, Cédric Olivier | |
dc.contributor.author | Barré, Sébastien | |
dc.contributor.author | Correa Shokiche, Carlos | |
dc.contributor.author | Schaad, Laura | |
dc.contributor.author | Röthlisberger, Raphael | |
dc.contributor.author | Wnuk, Monika L | |
dc.contributor.author | Daniel, Christoph | |
dc.contributor.author | Khoma, Oleksiy-Zakhar | |
dc.contributor.author | Tschanz, Stefan A. | |
dc.contributor.author | Reyes Aguirre, Mauricio Antonio | |
dc.contributor.author | Djonov, Valentin Georgiev | |
dc.date.accessioned | 2024-10-25T13:29:01Z | |
dc.date.available | 2024-10-25T13:29:01Z | |
dc.date.issued | 2018-03-01 | |
dc.description.abstract | In the last decades the contrast-enhanced microCT-imaging of whole animal kidney became increasingly important. The visualization was mainly limited to middle-sized vessels. Since modern desktop microCT-scanners provide the necessary detail resolution, we developed an approach for rapid visualization and consistent assessment of kidney vasculature and glomeruli number. This method is based on μAngiofil®, a new polymerizing contrast agent with homogenous X-ray absorption, which provides continuous filling of the complete vasculature and enables correlative imaging approaches. For rapid and reliable kidney morphometry the microangioCT-datasets from GDNF+/- mice and their wildtype littermates were used. The results were obtained much faster compared to the current gold standard, histology-based stereology, and without processing artefacts. The histology-based morphometry was afterwards done on the same kidneys. Both approaches revealed that the GDNF+/- male mice had more than 30% fewer glomeruli. Futhermore, our approach allows defining sites of interest for further histological investigation, i.e., correlative morphology. The polymerized μAngiofil stays in perfused vessels and is auto-fluorescent what greatly facilitates matching of histological sections with microangioCT-data. The presented approach is time-efficient and reliable qualitative and quantitative methodology. Besides glomerular morphometry the microangioCT-data can be used for qualitative and quantitative analysis of the kidney vasculature and correlative morphology. | |
dc.description.sponsorship | Institut für Anatomie | |
dc.description.sponsorship | Institut für chirurgische Technologien und Biomechanik (ISTB) | |
dc.identifier.pmid | 29167169 | |
dc.identifier.publisherDOI | 10.1152/ajprenal.00099.2017 | |
dc.identifier.uri | https://boris-portal.unibe.ch/handle/20.500.12422/156833 | |
dc.language.iso | en | |
dc.publisher | American Physiological Society | |
dc.relation.ispartof | American journal of physiology - renal physiology | |
dc.relation.issn | 0363-6127 | |
dc.relation.organization | DCD5A442BCD7E17DE0405C82790C4DE2 | |
dc.relation.organization | DCD5A442BCD5E17DE0405C82790C4DE2 | |
dc.relation.organization | 5EBDFFD4994748B4B44FD17D5E463CFB | |
dc.subject | contrast agent kidney morphometry micro-CT stereology vascular imaging | |
dc.subject.ddc | 600 - Technology::610 - Medicine & health | |
dc.subject.ddc | 500 - Science::570 - Life sciences; biology | |
dc.title | Cutting-edge microangio-CT: new dimensions in vascular imaging and kidney morphometry. | |
dc.type | article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | F499 | |
oaire.citation.issue | 3 | |
oaire.citation.startPage | F493 | |
oaire.citation.volume | 314 | |
oairecerif.author.affiliation | Institut für Anatomie | |
oairecerif.author.affiliation | Institut für Anatomie | |
oairecerif.author.affiliation | Institut für Anatomie | |
oairecerif.author.affiliation | Institut für chirurgische Technologien und Biomechanik (ISTB) | |
oairecerif.author.affiliation | Institut für Anatomie | |
oairecerif.author.affiliation | Institut für Anatomie | |
oairecerif.author.affiliation | Institut für Anatomie | |
oairecerif.author.affiliation | Institut für Anatomie | |
oairecerif.author.affiliation | Institut für chirurgische Technologien und Biomechanik (ISTB) | |
oairecerif.author.affiliation | Institut für Anatomie | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.contributor.role | creator | |
unibe.description.ispublished | pub | |
unibe.eprints.legacyId | 108948 | |
unibe.journal.abbrevTitle | AM J PHYSIOL-RENAL | |
unibe.refereed | TRUE | |
unibe.subtype.article | journal |