• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Gaussian process prediction of the stress-free configuration of pre-deformed soft tissues: Application to the human cornea.
 

Gaussian process prediction of the stress-free configuration of pre-deformed soft tissues: Application to the human cornea.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.95280
Publisher DOI
10.1016/j.medengphy.2016.01.012
PubMed ID
26920075
Description
Image-based modeling is a popular approach to perform patient-specific biomechanical simulations. One constraint of this technique is that the shape of soft tissues acquired in-vivo is deformed by the physiological loads. Accurate simulations require determining the existing stress in the tissues or their stress-free configurations. This process is time consuming, which is a limitation to the dissemination of numerical planning solutions to clinical practice. In this study, we propose a method to determine the stress-free configuration of soft tissues using a Gaussian process (GP) regression. The prediction relies on a database of pre-calculated results to enable real time predictions. The application of this technique to the human cornea showed a level of accuracy five to ten times higher than the accuracy of the topographic device used to obtain the patients' anatomy; results showed that for almost all optical indices, the predicted curvature error did not exceed 0.025 D, while the wavefront aberration percentage error did not overcome 5%. In this context, we believe that GP models are suitable for predicting the stress free configuration of the cornea and can be used in planning tools based on patient-specific finite element simulations. Due to the high level of accuracy required in ophthalmology, this approach is likely to be appropriate for other applications requiring the definition of the relaxed shape of soft tissues.
Date of Publication
2016-04
Publication Type
Article
Subject(s)
500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
600 Technology > 620 Engineering
Keyword(s)
Biomechanics
•
Cornea
•
Finite-element
•
Gaussian process
•
Prediction
•
Stress-free
Language(s)
en
Contributor(s)
Businaro, Elena
Institut für chirurgische Technologien und Biomechanik (ISTB)
Studer, Harald
Pajic, Bojan
Büchler, Philippeorcid-logo
Institut für chirurgische Technologien und Biomechanik (ISTB)
Additional Credits
Institut für chirurgische Technologien und Biomechanik (ISTB)
Series
Medical engineering & physics
Publisher
Elsevier
ISSN
1350-4533
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo