• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Respiratory motion modelling for MR-guided lung cancer radiotherapy: model development and geometric accuracy evaluation.
 

Respiratory motion modelling for MR-guided lung cancer radiotherapy: model development and geometric accuracy evaluation.

Options
  • Details
  • Files
BORIS DOI
10.48350/196950
Publisher DOI
10.1088/1361-6560/ad222f
PubMed ID
38266298
Description
Objective.Respiratory motion of lung tumours and adjacent structures is challenging for radiotherapy. Online MR-imaging cannot currently provide real-time volumetric information of the moving patient anatomy, therefore limiting precise dose delivery, delivered dose reconstruction, and downstream adaptation methods.Approach.We tailor a respiratory motion modelling framework towards an MR-Linac workflow to estimate the time-resolved 4D motion from real-time data. We develop a multi-slice acquisition scheme which acquires thick, overlapping 2D motion-slices in different locations and orientations, interleaved with 2D surrogate-slices from a fixed location. The framework fits a motion model directly to the input data without the need for sorting or binning to account for inter- and intra-cycle variation of the breathing motion. The framework alternates between model fitting and motion-compensated super-resolution image reconstruction to recover a high-quality motion-free image and a motion model. The fitted model can then estimate the 4D motion from 2D surrogate-slices. The framework is applied to four simulated anthropomorphic datasets and evaluated against known ground truth anatomy and motion. Clinical applicability is demonstrated by applying our framework to eight datasets acquired on an MR-Linac from four lung cancer patients.Main results.The framework accurately reconstructs high-quality motion-compensated 3D images with 2 mm3isotropic voxels. For the simulated case with the largest target motion, the motion model achieved a mean deformation field error of 1.13 mm. For the patient cases residual error registrations estimate the model error to be 1.07 mm (1.64 mm), 0.91 mm (1.32 mm), and 0.88 mm (1.33 mm) in superior-inferior, anterior-posterior, and left-right directions respectively for the building (application) data.Significance.The motion modelling framework estimates the patient motion with high accuracy and accurately reconstructs the anatomy. The image acquisition scheme can be flexibly integrated into an MR-Linac workflow whilst maintaining the capability of online motion-management strategies based on cine imaging such as target tracking and/or gating.
Date of Publication
2024-02-19
Publication Type
Article
Subject(s)
500 Science > 530 Physics
600 Technology > 610 Medicine & health
Keyword(s)
IGRT MR-Linac MR-guided radiotherapy motion management motion model respiratory motion
Language(s)
en
Contributor(s)
Eiben, Björn
Bertholet, Jennyorcid-logo
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik
Universitätsklinik für Radio-Onkologie
Tran, Elena H
Wetscherek, Andreas
Shiarli, Anna-Maria
Nill, Simeon
Oelfke, Uwe
McClelland, Jamie R
Additional Credits
Universitätsklinik für Radio-Onkologie - Medizinische Strahlenphysik
Series
Physics in medicine and biology
Publisher
IOP Publishing
ISSN
1361-6560
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo