• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Characterization of dynamic compliance of the respiratory system in healthy anesthetized dogs.

Characterization of dynamic compliance of the respiratory system in healthy anesthetized dogs.

Details
Files
DOI
10.48620/84510
Publisher DOI
10.3389/fvets.2024.1490494
PubMed ID
39669660
Abstract
Introduction
In clinical practice, evaluating dynamic compliance of the respiratory system (Cdyn) could provide valuable insights into respiratory mechanics. Reference values of Cdyn based on body weight have been reported, but various factors may affect them and the evidence is scanty. This study aimed to establish a reference interval for Cdyn and identify associated variables.
Methods
Data were collected from 515 client-owned dogs requiring anesthesia, excluding those with lower airway disease. The dogs were anesthetized, the tracheas intubated, and lungs ventilated at clinicians' discretion across 11 centers in six countries, with no restrictions on anesthesia protocols or ventilation settings, except avoiding inspiratory pauses. Three Cdyn measurements from three consecutive breaths per dog were recorded using a standardized form, which also documented factors affecting Cdyn identified through literature and an online survey. Various spirometry technologies were used. The substantial variance in Cdyn measurements led to a comprehensive analysis using a multiple linear regression model. Multicollinearity (variables highly correlated with each other) was addressed by investigating, transforming, or excluding factors. Initial simple linear regression assessed each variable's individual effect on Cdyn, followed by a multiple linear regression model constructed via stepwise forward selection and backward elimination.
Results
The best-fitting model identified a linear relationship between Cdyn and body mass when the following conditions were met: high BCS (Body Condition Score), orotracheal tubes <7% smaller than predicted, the use of a D-lite flow sensor, and the absence of a high FIO2 (>80%) exposure for more than 10 minutes before Cdyn measurement. In cases where these conditions were not met, additional factors needed to be incorporated into the model. Low (1/9, 2/9, 3/9) and medium (4/9, 5/9) BCS, an orotracheal tube of the predicted size or larger and longer inspiratory times were associated with increased Cdyn. The use of alternative spirometry sensors, including Ped-lite, or prolonged exposure to high FIO2 levels resulted in decreased Cdyn.
Conclusion And Clinical Relevance
Establishing a reference interval for Cdyn proved challenging. A single reference interval may be misleading or unhelpful in clinical practice. Nevertheless, this study offers valuable insights into the factors affecting Cdyn in healthy anesthetized dogs, which should be considered in clinical assessments.
Date Issued
2024
Publication Type
Article
Subject(s)
600 Technology > 630 Agriculture
500 Science > 570 Life sciences; biology
Subjects
anesthesia
•
compliance
•
dogs
•
dynamic compliance
•
monitoring
•
respiratory mechanics
•
spirometry
•
ventilation
Language(s)
en
Author(s)
Raillard, Mathieu  
Mosing, Martina
Raisis, Anthea
Auckburally, Adam
Beaumont, Georgina
Downing, Frances
Heselton, Charlotte
MacFarlane, Paul
Portier, Karine
Robertson, Josephine
Soares, Joao Henrique Neves
Steblaj, Barbara
Wringe, Elliot
Levionnois, Olivier L.  
Department of Clinical Veterinary Medicine, Anaesthesiology  
Additional Credits
Department of Clinical Veterinary Medicine  
Department of Clinical Veterinary Medicine, Anaesthesiology  
Journal
Frontiers in Veterinary Science
Publisher
Frontiers Media
ISSN
2297-1769
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify