  3. A Physiological Controller for Turbodynamic Ventricular Assist Devices Based on a Measurement of the Left Ventricular Volume
 

A Physiological Controller for Turbodynamic Ventricular Assist Devices Based on a Measurement of the Left Ventricular Volume

Options
  • Details
Publisher DOI
10.1111/aor.12225
PubMed ID
24256168
Description
The current article presents a novel physiological control algorithm for ventricular assist devices (VADs), which is inspired by the preload recruitable stroke work. This controller adapts the hydraulic power output of the VAD to the end-diastolic volume of the left ventricle. We tested this controller on a hybrid mock circulation where the left ventricular volume (LVV) is known, i.e., the problem of measuring the LVV is not addressed in the current article. Experiments were conducted to compare the response of the controller with the physiological and with the pathological circulation, with and without VAD support. A sensitivity analysis was performed to analyze the influence of the controller parameters and the influence of the quality of the LVV signal on the performance of the control algorithm. The results show that the controller induces a response similar to the physiological circulation and effectively prevents over- and underpumping, i.e., ventricular suction and backflow from the aorta to the left ventricle, respectively. The same results are obtained in the case of a disturbed LVV signal. The results presented in the current article motivate the development of a robust, long-term stable sensor to measure the LVV.
Date of Publication
2013-11-21
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Frank-Starling law
•
Physiological control
•
Ventricular assist device
•
Volume measurement
Language(s)
en
Contributor(s)
Ochsner, Gregor
Amacher, Raffael
Wilhelm, Markus J.
Vandenberghe, Stijn
ARTORG Center - Cardiovascular Engineering (Heart)
Tevaearai, Hendrik
Universitätsklinik für Herz- und Gefässchirurgie
Plass, André
Amstutz, Alois
Falk, Volkmar
Schmid Daners, Marianne
Additional Credits
ARTORG Center - Cardiovascular Engineering (Heart)
Universitätsklinik für Herz- und Gefässchirurgie
Series
Artificial organs
Publisher
Wiley-Blackwell
ISSN
0160-564X
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo