Publication:
Non-contrast enhanced functional lung MRI in children: report on 900 own measurements using matrix-pencil decomposition (MP-) MRI

cris.virtual.author-orcid0000-0003-1140-9437
cris.virtual.author-orcid0000-0003-4754-1608
cris.virtual.author-orcid0000-0002-9519-9328
cris.virtual.author-orcid0000-0002-6184-5280
cris.virtual.author-orcid0000-0001-7720-3445
cris.virtual.author-orcid0000-0001-8731-0885
cris.virtual.author-orcid0000-0002-5239-1571
cris.virtual.author-orcid0000-0003-1741-5221
cris.virtualsource.author-orcidf8d11a09-0102-425d-b657-584019d5e2a1
cris.virtualsource.author-orcid734076ee-7ee1-4f0e-ad01-c8e43737aace
cris.virtualsource.author-orcidc78a191b-4014-4c0e-9c6f-c43327df9b50
cris.virtualsource.author-orcide2cc911c-ee16-4177-9c75-648bb31ce324
cris.virtualsource.author-orcidcfe2ae7b-9f4d-4ca7-8286-dafe50ecbe8b
cris.virtualsource.author-orcid211bcca9-f222-47a7-8750-326640404b91
cris.virtualsource.author-orcidba4c1e16-4d17-4432-b543-c2c969ab5883
cris.virtualsource.author-orcid9d060df1-6e3a-422b-a884-ab710b0cf486
cris.virtualsource.author-orcid7457a40a-9226-489a-9650-a936c14fb53f
cris.virtualsource.author-orcide3d61a65-3b66-4cf4-a428-a08ddc854d50
datacite.rightsopen.access
dc.contributor.authorStreibel, Carmen
dc.contributor.authorBauman, Grzegorz
dc.contributor.authorBieri, Oliver
dc.contributor.authorPusterla, Orso
dc.contributor.authorStranzinger, Enno
dc.contributor.authorWillers, C. Corin
dc.contributor.authorCurdy, Marion
dc.contributor.authorCasaulta, Carmen
dc.contributor.authorFrauchiger, Bettina Sarah
dc.contributor.authorKorten, Insa
dc.contributor.authorYammine, Sophie
dc.contributor.authorSalem, Yasmin
dc.contributor.authorLatzin, Philipp
dc.contributor.authorKieninger, Elisabeth
dc.date.accessioned2025-04-24T14:08:02Z
dc.date.available2025-04-24T14:08:02Z
dc.date.issued2025-03-13
dc.description.abstractObjectives: Functional imaging of the lungs enables a spatially resolved examination of pulmonary ventilation and perfusion. Non-contrast-enhanced (NCE) magnetic resonance imaging (MRI) techniques do not require specialized set-ups (e.g., hyperpolarized gases), but are applicable on standard clinical MRI scanners. Since patients are not exposed to ionizing radiation during the examinations, NCE-MRI is highly attractive for use in pediatrics, especially in children with chronic lung diseases requiring repeated follow-up measurements. Study design: We report on our own experience of more than 900 NCE-MRI measurements in children over seven years using matrix pencil decomposition (MP-)MRI. We present original data, i.e., clinical cases in which MP-MRI helped in clinical decision-making together with valuable practical points. Results: At our center, an optimized workflow including a child-friendly setting and automated provision of outcome protocols led to great acceptance of functional NCE-MRI in patients and clinicians. Within this setting, regular MP-MRI measurements were successfully implemented into clinical routine and proved to be very helpful for surveillance and specific clinical decision-making. We present exemplary cases illustrating the potential of NCE-MRI as a diagnostic tool. Conclusion: In this article, we summarize our unique experience of a large number of MP-MRI measurements. We give an overview on our workflow including standardized and automated analysis and reporting. The exemplary cases from different disease groups illustrate its value in the clinical setting. In conclusion, visualizing regional functional deficits and respective underlying pathophysiological nature of lung impairment seems promising for increasing use of NCE-MRI in the future.
dc.description.sponsorshipGraduate School for Health Sciences (GHS)
dc.description.sponsorshipInstitute of Diagnostic, Interventional and Paediatric Radiology
dc.description.sponsorshipClinic of Paediatric Medicine
dc.identifier.doi10.48620/87537
dc.identifier.pmid40151183
dc.identifier.publisherDOI10.3389/fped.2025.1519148
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/208002
dc.language.isoen
dc.publisherFrontiers Media
dc.relation.ispartofFrontiers in Pediatrics
dc.relation.issn2296-2360
dc.subjectMP-MRI
dc.subjectchildren
dc.subjectfunctional lung MRI
dc.subjectlung function
dc.subjectpulmonology
dc.titleNon-contrast enhanced functional lung MRI in children: report on 900 own measurements using matrix-pencil decomposition (MP-) MRI
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.volume13
oairecerif.author.affiliationGraduate School for Health Sciences (GHS)
oairecerif.author.affiliationInstitute of Diagnostic, Interventional and Paediatric Radiology
oairecerif.author.affiliationClinic of Paediatric Medicine
oairecerif.author.affiliationClinic of Paediatric Medicine
oairecerif.author.affiliationClinic of Paediatric Medicine
oairecerif.author.affiliationClinic of Paediatric Medicine
oairecerif.author.affiliationDepartment of Paediatrics
oairecerif.author.affiliationDepartment of Paediatrics
oairecerif.author.affiliationClinic of Paediatric Medicine
oairecerif.author.affiliationClinic of Paediatric Medicine
oairecerif.author.affiliation2Department of Paediatrics
unibe.additional.sponsorshipGraduate School for Health Sciences (GHS)
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.rolecorresponding author
unibe.description.ispublishedpub
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
fped-2-1519148.pdf
Size:
139.06 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by/4.0
Content:
published

Collections