Publication:
The effect of threshold level on bone segmentation of cranial base structures from CT and CBCT images.

cris.virtual.author-orcid0000-0002-0665-238X
cris.virtualsource.author-orcid52df92a5-8325-416f-b8d5-3a72dd8d9b66
cris.virtualsource.author-orcida7c6fd15-7822-4377-b3e4-6d41da9fb429
cris.virtualsource.author-orcide2106a9d-1ff3-462f-b2d4-895d1e0825bb
datacite.rightsopen.access
dc.contributor.authorFriedli, Luca
dc.contributor.authorKloukos, Dimitrios
dc.contributor.authorKanavakis, Georgios
dc.contributor.authorHalazonetis, Demetrios
dc.contributor.authorGkantidis, Nikolaos
dc.date.accessioned2024-10-05T09:47:59Z
dc.date.available2024-10-05T09:47:59Z
dc.date.issued2020-04-30
dc.description.abstractThe use of a single grey intensity threshold is one of the most straightforward and widely used methods to segment cranial base surface models from a 3D radiographic volume. In this study we used thirty Cone Beam Computer Tomography (CBCT) scans from three different machines and ten CT scans of growing individuals to test the effect of thresholding on the subsequently produced anterior cranial base surface models. From each scan, six surface models were generated using a range of voxel intensity thresholds. The models were then superimposed on a manually selected reference surface model, using an iterative closest point algorithm. Multivariate tests showed significant effects of the machine type, threshold value, and superimposition on the spatial position and the form of the created models. For both, CT and CBCT machines, the distance between the models, as well as the variation within each threshold category, was consistently increasing with the magnitude of difference between thresholds. The present findings highlight the importance of accurate anterior cranial base segmentation for reliable assessment of craniofacial morphology through surface superimposition or similar methods that utilize this anatomical structure as reference.
dc.description.numberOfPages11
dc.description.sponsorshipZahnmedizinische Kliniken, Klinik für Kieferorthopädie
dc.identifier.doi10.7892/boris.143917
dc.identifier.pmid32355261
dc.identifier.publisherDOI10.1038/s41598-020-64383-9
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/54840
dc.language.isoen
dc.publisherSpringer Nature
dc.relation.ispartofScientific reports
dc.relation.issn2045-2322
dc.relation.organizationDCD5A442C013E17DE0405C82790C4DE2
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleThe effect of threshold level on bone segmentation of cranial base structures from CT and CBCT images.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.issue1
oaire.citation.startPage7361
oaire.citation.volume10
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Kieferorthopädie
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Kieferorthopädie
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Kieferorthopädie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2020-05-11 19:03:57
unibe.description.ispublishedpub
unibe.eprints.legacyId143917
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
s41598-020-64383-9.pdf
Size:
2.03 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by/4.0
Content:
published

Collections