• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Cameo and intaglio surface stability and variability of additively, subtractively, and conventionally manufactured occlusal devices after long-term storage.
 

Cameo and intaglio surface stability and variability of additively, subtractively, and conventionally manufactured occlusal devices after long-term storage.

Options
  • Details
  • Files
BORIS DOI
10.48350/198405
Publisher DOI
10.1016/j.prosdent.2024.06.008
PubMed ID
38955603
Description
STATEMENT OF PROBLEM

Additive and subtractive manufacturing have become alternative technologies for fabricating occlusal devices. However, knowledge of the long-term stability of occlusal devices fabricated using these recent technologies is limited.

PURPOSE

The purpose of this in vitro study was to evaluate the cameo and intaglio surface stability and variability of additively, subtractively, and conventionally manufactured occlusal devices after 18 months of storage.

MATERIAL AND METHODS

A standard tessellation language (STL) file of a dentate maxillary typodont was used to design a master occlusal device. The STL file of this design was used to fabricate occlusal devices additively either with a digital light processing (AM-1) or a continuous liquid interface production (AM-2) printer, subtractively with 2 different 5-axis milling units (SM-1 and SM-2), and conventionally (TM-HP) (n=10). STL files of each device's cameo and intaglio surfaces were generated using a laboratory scanner after fabrication and after 18 months of storage in a moist environment. These generated files were imported into an analysis software program (Geomagic Control X) to analyze the dimensional stability of tested devices by using the root mean square method. The average deviation values defined the variability of measured changes over time. Cameo and intaglio surface deviations were analyzed using the Kruskal-Wallis and Dunn tests, while the variability of measured deviations was analyzed with 1-way analysis of variance and the Tukey HSD tests (α=.05).

RESULTS

Significant differences were observed among tested devices when the intaglio surface deviations and the cameo surface variability were considered (P<.001). SM-2 had significantly higher intaglio surface deviations than AM-1, SM-1, and AM-2 (P≤.036). Among the test groups, AM-1 had the greatest cameo surface variability (P≤.004).

CONCLUSIONS

SM-2 resulted in lower intaglio surface stability than the additive and the other subtractive manufacturing technologies, while AM-1 led to the highest cameo surface variability among the test groups.
Date of Publication
2024-09
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Orgev, Ahmet
Dönmez, Mustafa Borga
Zahnmedizinische Kliniken (ZMK) Universität Bern
Almogbel, Lolowh
Cakmak, Gülce
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Marques, Vinicius Rizzo
Kahveci, Cigdem
Yilmaz, Burak
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Zahnmedizinische Kliniken (ZMK) - Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
Additional Credits
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Zahnmedizinische Kliniken (ZMK) Universität Bern
Series
The journal of prosthetic dentistry
Publisher
Elsevier
ISSN
1097-6841
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo