Publication:
In situ and in vitro comparison of laser fluorescence with visual inspection in detecting occlusal caries lesions

cris.virtualsource.author-orcid36a8109c-7d04-4581-84a3-a3914e2d5365
datacite.rightsopen.access
dc.contributor.authorde Paula, Andréia Bolzan
dc.contributor.authorCampos, Juliana Alvares Duarte Bonini
dc.contributor.authorDiniz, Michele Baffi
dc.contributor.authorHebling, Josimeri
dc.contributor.authorDe Almeida Rodrigues, Jonas
dc.date.accessioned2024-10-10T21:13:01Z
dc.date.available2024-10-10T21:13:01Z
dc.date.issued2011
dc.description.abstractThe aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.
dc.description.numberOfPages5
dc.description.sponsorshipZahnmedizinische Kliniken, Klinik für Zahnerhaltung
dc.identifier.doi10.7892/boris.4450
dc.identifier.isi000284274100001
dc.identifier.pmid19784712
dc.identifier.publisherDOI10.1007/s10103-009-0731-y
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/75104
dc.language.isoen
dc.publisherSpringer-Verlag
dc.publisher.placeLondon
dc.relation.ispartofLasers in medical science
dc.relation.issn0268-8921
dc.relation.organizationDCD5A442BE8FE17DE0405C82790C4DE2
dc.titleIn situ and in vitro comparison of laser fluorescence with visual inspection in detecting occlusal caries lesions
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage5
oaire.citation.issue1
oaire.citation.startPage1
oaire.citation.volume26
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Zahnerhaltung
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2019-10-22 18:51:19
unibe.description.ispublishedpub
unibe.eprints.legacyId4450
unibe.journal.abbrevTitleLASER MED SCI
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
10103_2009_Article_731.pdf
Size:
112.92 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections