• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Quantitative contrast echocardiographic assessment of collateral derived myocardial perfusion during elective coronary angioplasty
 

Quantitative contrast echocardiographic assessment of collateral derived myocardial perfusion during elective coronary angioplasty

Options
  • Details
Publisher DOI
10.1136/heart.86.3.324
PubMed ID
11514489
Description
OBJECTIVE

To determine whether myocardial contrast echocardiography can be used to quantify collateral derived myocardial flow in humans.

METHODS

In 25 patients undergoing coronary angioplasty, a collateral flow index (CFI) was determined using intracoronary wedge pressure distal to the stenosis to be dilated, with simultaneous mean aortic pressure measurements. During balloon occlusion, echo contrast was injected into both main coronary arteries simultaneously. Echocardiography of the collateral receiving myocardial area was performed. The time course of myocardial contrast enhancement in images acquired at end diastole was quantified by measuring pixel intensities (256 grey units) within a region of interest. Perfusion variables, such as background subtracted peak pixel intensity and contrast transit rate, were obtained from a fitted gamma variate curve.

RESULTS

16 patients had a left anterior descending coronary artery stenosis, four had a left circumflex coronary artery stenosis, and five had a right coronary artery stenosis. The mean (SD) CFI was 19 (12)% (range 0-47%). Mean contrast transit rate was 11 (8) seconds. In 17 patients, a significant collateral contrast effect was observed (defined as peak pixel intensity more than the mean + 2 SD of background). Peak pixel intensity was linearly related to CFI in patients with a significant contrast effect (p = 0.002, r = 0.69) as well as in all patients (p = 0.0003, r = 0.66).

CONCLUSIONS

Collateral derived perfusion of myocardial areas at risk can be demonstrated using intracoronary echo contrast injections. The peak echo contrast effect is directly related to the magnitude of collateral flow.
Date of Publication
2001-09
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
De Marchi, Stefanoorcid-logo
Universitätsklinik für Kardiologie
Schwerzmann, Markusorcid-logo
Universitätsklinik für Kardiologie
Fleisch, M.
Billinger, M.
Meier, B.
Seiler, Christian
Universitätsklinik für Kardiologie
Additional Credits
Universitätsklinik für Kardiologie
Series
Heart (British Cardiac Society)
Publisher
BMJ Publishing Group
ISSN
1468-201X
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo