Publication:
Updated practice guideline for dual-energy X-ray absorptiometry (DXA).

cris.virtualsource.author-orcidbacb81f9-08a4-498c-b860-e3be8396d189
datacite.rightsopen.access
dc.contributor.authorSlart, Riemer H J A
dc.contributor.authorPunda, Marija
dc.contributor.authorAli, Dalal S
dc.contributor.authorBazzocchi, Alberto
dc.contributor.authorBock, Oliver
dc.contributor.authorCamacho, Pauline
dc.contributor.authorCarey, John J
dc.contributor.authorColquhoun, Anita
dc.contributor.authorCompston, Juliet
dc.contributor.authorEngelke, Klaus
dc.contributor.authorErba, Paola A
dc.contributor.authorHarvey, Nicholas C
dc.contributor.authorKrueger, Diane
dc.contributor.authorLems, Willem F
dc.contributor.authorLewiecki, E Michael
dc.contributor.authorMorgan, Sarah
dc.contributor.authorMoseley, Kendall F
dc.contributor.authorO'Brien, Christopher
dc.contributor.authorProbyn, Linda
dc.contributor.authorRhee, Yumie
dc.contributor.authorRichmond, Bradford
dc.contributor.authorSchousboe, John T
dc.contributor.authorShuhart, Christopher
dc.contributor.authorWard, Kate A
dc.contributor.authorVan den Wyngaert, Tim
dc.contributor.authorZhang-Yin, Jules
dc.contributor.authorKhan, Aliya A
dc.date.accessioned2024-11-01T11:46:17Z
dc.date.available2024-11-01T11:46:17Z
dc.date.issued2025-01
dc.description.abstractThe introduction of dual-energy X-ray absorptiometry (DXA) technology in the 1980s revolutionized the diagnosis, management and monitoring of osteoporosis, providing a clinical tool which is now available worldwide. However, DXA measurements are influenced by many technical factors, including the quality control procedures for the instrument, positioning of the patient, and approach to analysis. Reporting of DXA results may be confounded by factors such as selection of reference ranges for T-scores and Z-scores, as well as inadequate knowledge of current standards for interpretation. These points are addressed at length in many international guidelines but are not always easily assimilated by practising clinicians and technicians. Our aim in this report is to identify key elements pertaining to the use of DXA in clinical practice, considering both technical and clinical aspects. Here, we discuss technical aspects of DXA procedures, approaches to interpretation and integration into clinical practice, and the use of non-bone mineral density measurements, such as a vertebral fracture assessment, in clinical risk assessment.
dc.description.numberOfPages25
dc.description.sponsorshipClinic of Osteoporosis
dc.identifier.doi10.48620/75959
dc.identifier.pmid39316095
dc.identifier.publisherDOI10.1007/s00259-024-06912-6
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/125303
dc.language.isoen
dc.relation.ispartofEuropean journal of nuclear medicine and molecular imaging
dc.relation.issn1619-7089
dc.subjectDual-energy X-ray absorptiometry (DXA)
dc.subjectPractice guideline
dc.subjectProcedures
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleUpdated practice guideline for dual-energy X-ray absorptiometry (DXA).
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage563
oaire.citation.issue2
oaire.citation.startPage539
oaire.citation.volume52
oairecerif.author.affiliationClinic of Osteoporosis
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.description.ispublishedpub
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
s00259-024-06912-6.pdf
Size:
2.71 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by/4.0
Content:
published

Collections