Windowed Radon Transform for Robust Speed-of-Sound Imaging With Pulse-Echo Ultrasound

Options
  • Details
  • Files
BORIS DOI
10.48620/86872
Official URL
https://ieeexplore.ieee.org/document/10363357
Publisher DOI
10.1109/tmi.2023.3343918
PubMed ID
38109237
Description
In recent years, methods estimating the spatial distribution of tissue speed of sound with pulse-echo ultrasound are gaining considerable traction. They can address limitations of B-mode imaging, for instance in diagnosing fatty liver diseases. Current state-of-the-art methods relate the tissue speed of sound to local echo shifts computed between images that are beamformed using restricted transmit and receive apertures. However, the aperture limitation affects the robustness of phase-shift estimations and, consequently, the accuracy of reconstructed speed-of-sound maps. Here, we propose a method based on the Radon transform of image patches able to estimate local phase shifts from full-aperture images. We validate our technique on simulated, phantom and in-vivo data acquired on a liver and compare it with a state-of-the-art method. We show that the proposed method enhances the stability to changes of beamforming speed of sound and to a reduction of the number of insonifications. In particular, the deployment of pulse-echo speed-of-sound estimation methods onto portable ultrasound devices can be eased by the reduction of the number of insonifications allowed by the proposed method.
Date of Publication
2024-04-03
Publication Type
Article
Subject(s)
500 Science > 530 Physics
Language(s)
en
Contributor(s)
Beuret, Samuel
Hériard-Dubreuil, Baptiste
Korta Martiartu, Naiara
Institute of Applied Physics (IAP)
Institute of Applied Physics, Biomedical Photonics
Jaeger, Michael
Institute of Applied Physics (IAP)
Institute of Applied Physics, Biomedical Photonics
Thiran, Jean-Philippe
Additional Credits
Institute of Applied Physics (IAP)
Institute of Applied Physics, Biomedical Photonics
Series
IEEE Transactions on Medical Imaging
Publisher
Institute of Electrical and Electronics Engineers
ISSN
0278-0062
1558-254X
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo