• LOGIN
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publication
  • Projects
  • Funding
  • Research Data
  • Organizations
  • Researchers
  • LOGIN
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Influence of patient motion on definition of typical cephalometric reference points in digital horizontally scanning cephalometric radiography.
 

Influence of patient motion on definition of typical cephalometric reference points in digital horizontally scanning cephalometric radiography.

Options
  • Details
BORIS DOI
10.48620/86843
Date of Publication
March 17, 2025
Publication Type
Article
Division/Institute

School of Dental Medi...

School of Dental Medi...

Author
Martin, Kim
School of Dental Medicine, Clinic of Oral Surgery and Stomatology
Katsaros, Christos
School of Dental Medicine, Clinic of Orthodontics
Brylka, Robert
Schwanecke, Ulrich
Schulze, Ralforcid-logo
School of Dental Medicine, Clinic of Oral Surgery and Stomatology
School of Dental Medicine
Subject(s)

600 - Technology::610...

Series
Head and Face Medicine
ISSN or ISBN (if monograph)
1746-160X
Publisher
BioMed Central
Language
English
Publisher DOI
10.1186/s13005-025-00491-z
PubMed ID
40098004
Uncontrolled Keywords

Cephalometric analysi...

Diagnostic imaging

Digital cephalometric...

Head movement

Scanning technique

Description
Background
The aim of this study was to investigate the effect of defined head-motion during x-ray exposure on the identification accuracy of typical cephalometric reference points which form the basis of treatment planning.Methods
By means of a dry adult human skull and a precise motion simulation system digital Cephs are acquired while certain predefined movement patterns (shift, tilt and nodding with a motion amplitude from 5 - 50 mm) of the skull were executed. They represent the movements of children and adolescents, the main group for cephalometric radiographs.The scanning time was 9.4 s per Ceph. 10 typical landmark points of cephalometric analysis were identified by 20 observers on each Ceph twice. Using a non-motion image (Ceph0) as reference, displacement was computed as vectors relative to this image. Commonly used angles and vertical and horizontal distances were calculated.Results
Both inter-rater as well as intra-rater-reproducibility were perfect. There was very little change in the vertical distance N-Me, in contrast to the horizontal distance S-N which showed a large variation. So patient motion parallel to the scanning direction of the fan-beam-detector unit, heavily influence distances parallel to this direction. The ANB angle and the Maxillo-Mandibular Plane Angle (ANS-PNS to Me-Go) only varied by about 1-2°, but large enough to greatly influence a treatment plan.Conclusions
The study observed a severe influence on reference point location of motion patterns parallel to the scanning direction and also on clinically relevant distances parallel to the scanning direction. Therefore, we recommend to use a horizontal scanning direction, to minimise scanning time to a minimum, or to prefer a one-shot technique if possible. Future advancements in this field may include the integration of artificial intelligence or algorithms for the purpose of motion correction.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/207733
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
s13005-025-00491-z.pdftextAdobe PDF1.77 MBAttribution (CC BY 4.0)publishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: d1c7f7 [27.06. 13:56]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo