  2. Publications
  3. Trueness of the apical and middle root portion segments of 3D-printed removable die and alveolar cast designs manufactured using stereolithographic 3D printing.
 

Trueness of the apical and middle root portion segments of 3D-printed removable die and alveolar cast designs manufactured using stereolithographic 3D printing.

Options
  • Details
  • Files
BORIS DOI
10.48350/199093
Publisher DOI
10.1111/jopr.13911
PubMed ID
39023016
Description
PURPOSE

The present study evaluated the effects of the root portion design, segment (middle vs. apical), and part (die vs. cast) on the trueness of three-dimensional (3D)-printed removable die-cast complex.

MATERIAL AND METHODS

The trueness of apical and middle segments of the root portion of 45 3D-printed removable dies and casts with three different root portion designs (n = 15) was assessed using a metrology-grade computer program. The three removable dies and cast designs (root form [RF], conical [CON], and cylindric [CYL]) were created using professional computer-aided manufacturing computer programs (DentalCAD 3.1 Rijeka, and InLab CAD 22.0), and manufactured using stereolithographic 3D printer (Form3; FormLabs, Somerville, MA). Subsequently, the 3D-printed removable dies and casts were scanned by a single operator with an intraoral scanner (PrimeScan; Dentsply Sirona, Charlotte, NC), and their respective standard tessellation language files were aligned and compared to master reference files in a metrology-grade computer program (Geomagic Control X; 3D systems, Rock Hill, NC). The root mean square (RMS) values of the middle and apical segments for each removable die and cast were calculated and analyzed using a mixed model including a repeated measure 3-way analysis of variance (ANOVA) and post-hoc stepdown Bonferroni-corrected pairwise comparisons (α = 0.05).

RESULTS

A statistically significant 3-way interaction between factors was detected, suggesting that the part (removable die or alveolar cast) and their design affected the RMS values of their apical and middle root portion segment. (p = 0.045). The post-hoc analysis identified significant differences between RMS values of the apical segments of the CON and CYL removable dies (p = 0.005). Significant differences were observed between the middle and apical segments of the CON (p < 0.001) and RF removable die designs (p = 0.004). No statistically significant differences were noticed between the RMS of the different alveolar cast designs (p > 0.05). Significant differences were detected between the apical and middle segments of the same alveolar cast design (p < 0.05).

CONCLUSIONS

For the manufacturing trinomial and 3D printing strategy used in the present study, the interaction of the part, design, and segment affected the trueness of removable dies and alveolar casts. The trueness was higher on the middle segment on removable dies and alveolar casts in all designs used, except for CYL removable dies, where the trueness difference between segments was small. Higher trueness values may be achieved with designs with simple apical segment geometries.
Date of Publication
2026-06
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
3D printing CAD‐CAM fixed prosthodontics removable dies trueness
Language(s)
en
Contributor(s)
Azpiazu-Flores, Francisco X
Johnston, William M
Morton, Dean
Lin, Wei-Shao
Yilmaz, Burak
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Zahnmedizinische Kliniken (ZMK) Universität Bern
Additional Credits
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Zahnmedizinische Kliniken (ZMK) Universität Bern
Series
Journal of prosthodontics
Publisher
Wiley
ISSN
1532-849X
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo