Publication:
Transcranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation

cris.virtual.author-orcid0000-0002-5472-5221
cris.virtualsource.author-orcidc796a860-c7f6-4611-8dfe-34b348fd2f02
cris.virtualsource.author-orcid937eba74-cbfe-4394-b434-91d9e368cf70
cris.virtualsource.author-orcid31134751-5aa4-429b-82a9-a4f94bac9190
cris.virtualsource.author-orcidd73f6cf6-4a67-4870-9076-e185a1726ff0
cris.virtualsource.author-orcid101f1394-72d5-4dda-b28f-666a3dee6c70
cris.virtualsource.author-orcidfb99e59d-56d8-4e1d-87a2-10152d09d1ca
cris.virtualsource.author-orcid1aff97de-3aad-4eff-8aee-364c31210230
datacite.rightsopen.access
dc.contributor.authorErdoes, Gabor
dc.contributor.authorBasciani, Reto Marco
dc.contributor.authorHuber, Christoph
dc.contributor.authorStortecky, Stefan
dc.contributor.authorWenaweser, Peter Martin
dc.contributor.authorWindecker, Stephan
dc.contributor.authorCarrel, Thierry
dc.contributor.authorEberle, Balthasar
dc.date.accessioned2024-12-13T15:22:39Z
dc.date.available2024-12-13T15:22:39Z
dc.date.issued2012
dc.description.abstractTranscatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.
dc.description.numberOfPages7
dc.description.sponsorshipUniversitätsklinik für Kardiologie
dc.description.sponsorshipUniversitätsklinik für Herz- und Gefässchirurgie
dc.description.sponsorshipUniversitätsklinik für Anästhesiologie und Schmerztherapie
dc.identifier.doi10.7892/boris.6052
dc.identifier.isi000302021300021
dc.identifier.pmid22423058
dc.identifier.publisherDOI10.1093/ejcts/ezr068
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/191901
dc.language.isoen
dc.publisherOxford University Press
dc.publisher.placeOxford
dc.relation.ispartofEuropean journal of cardio-thoracic surgery
dc.relation.issn1010-7940
dc.relation.organizationDCD5A442BADCE17DE0405C82790C4DE2
dc.relation.organizationDCD5A442BADFE17DE0405C82790C4DE2
dc.relation.organizationDCD5A442BB15E17DE0405C82790C4DE2
dc.titleTranscranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage83; discussion 783
oaire.citation.issue4
oaire.citation.startPage778
oaire.citation.volume41
oairecerif.author.affiliationUniversitätsklinik für Anästhesiologie und Schmerztherapie
oairecerif.author.affiliationUniversitätsklinik für Anästhesiologie und Schmerztherapie
oairecerif.author.affiliationUniversitätsklinik für Herz- und Gefässchirurgie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Herz- und Gefässchirurgie
oairecerif.author.affiliationUniversitätsklinik für Anästhesiologie und Schmerztherapie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2019-10-23 03:59:56
unibe.description.ispublishedpub
unibe.eprints.legacyId6052
unibe.journal.abbrevTitleEUR J CARDIO-THORAC SURG
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
ezr068.pdf
Size:
131.61 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections