• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Interruption of machine milking in dairy cows: effects on intramammary pressure and milking characteristics
 

Interruption of machine milking in dairy cows: effects on intramammary pressure and milking characteristics

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.115920
Publisher DOI
10.1017/S0022029900031289
Description
Experiments were designed to test the hypothesis that milk ejection rate decreases during milking, thereby causing insufficient refill of the cistern and decreasing milk flow rate towards the end of milking. In a first series of experiments machine milking of the left front quarters of 11 cows was interrupted for 2 min after removal of 25, 50 or 75% of expected total milk yield, while milking was continued in the other three quarters. Milk flow was recorded during machine-on times. Intramammary pressure (IMP) was recorded during premilking teat stimulation and during interruption of milking. IMP during interruption of milking decreased with decreasing amounts of milk remaining in the udder. The IMP did not change during these interruptions when they occurred after 25 and 50% of expected total milk yield was removed. Thus, the ejection rate could keep up with the milk flow or removal rate. However, IMP increased during interruption of milking following removal of 75% of total yield, although significantly so only in cows with a high milk flow rate. Obviously, more milk was removed than was transported to the cisternal cavity. It is likely that a reduced ejection rate caused the decreased milk flow rate. In a second series of experiments the pulsation ratio of the milking machine was changed from the usual 70:30 to 50:50 with the aim of reducing the milk flow rate and thus adapting to the ejection rate at the end of milking. The changed pulsation ratio caused a reduced peak flow rate and a prolonged high milk flow period, whereas the main flow rate did not change significantly.
Date of Publication
1995
Publication Type
Article
Language(s)
en
Contributor(s)
Pfeilsticker, Hans-Ulrich
Bruckmaier, Rupert
Department of Clinical Research and Veterinary Public Health, Veterinär-Physiologie
Blum, Jürg
Department of Clinical Research and Veterinary Public Health, Veterinär-Physiologie
Additional Credits
Department of Clinical Research and Veterinary Public Health, Veterinär-Physiologie
Series
Journal of dairy research
Publisher
Cambridge University Press
ISSN
0022-0299
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo