  3. Is personal physiology-based rapid prediction digital twin for minimal effective fentanyl dose better than standard practice: a pilot study protocol.
 

Is personal physiology-based rapid prediction digital twin for minimal effective fentanyl dose better than standard practice: a pilot study protocol.

Options
  • Details
BORIS DOI
10.48620/75949
Date of Publication
September 24, 2024
Publication Type
Article
Division/Institute

Institute of Clinical...

Author
Cukic, Milena
Annaheim, Simon
Bahrami, Floraorcid-logo
Institute of Clinical Chemistry
Defraeye, Thijs
De Nys, Katelijne
Jörger, Markus
Subject(s)

600 - Technology::610...

Series
BMJ Open
ISSN or ISBN (if monograph)
2044-6055
Publisher
BMJ Publishing Group
Language
English
Publisher DOI
10.1136/bmjopen-2024-085296
PubMed ID
39317494
Uncontrolled Keywords

Cancer pain

Information technolog...

Pain management

Palliative care

Description
Introduction
Patients with advanced cancer frequently suffer from chronic, severe disabling pain. Opioids such as morphine and fentanyl are commonly used to manage this pain. Transdermal drug delivery systems are important technologies for administering drugs in a non-invasive, continuous and controlled manner. Due to the narrow therapeutic range of fentanyl, individualised dosing is essential to avoid underdosing or overdosing. Standard clinical calculation tools for opioid rotation however do not include important patient characteristics that account for interindividual variability of opioid pharmacology.Methods And Analysis
We developed a clinical protocol to optimise individual fentanyl dosing in patients with advanced cancer switching from oral or intravenous opioids to transdermal fentanyl by using a physics-based digital twin (DT) that is fed by important clinical and physiological parameters. Individual tailoring of transdermal fentanyl therapy is an approach with the potential for personalised and effective care with an improved benefit-risk ratio. However, clinical validation of physics-based digital twins (PBDT) dosing is crucial to proving clinical benefit.Therapeutic drug monitoring will allow to validate the accuracy of PBDT predictions. Additional monitoring for breathing dynamics, sequential pain levels and fentanyl-related adverse events will contribute to evaluating the performance of PBDT-based dosing of transdermal fentanyl. The primary objective of the study is to develop an experimental protocol to validate DT-guided fentanyl dosing in patients with advanced cancer. This clinical study will bring individualised opioid dosing closer to clinical practice.Ethics And Dissemination
Study documents have been approved by the responsible Ethics Committee and study initiation is planned for late summer 2024. Data will be shared with the scientific community no more than 1 year following completion of the study and data assembly.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/125297
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
e085296.full.pdftextAdobe PDF697.38 KBAttribution-NonCommercial (CC BY-NC 4.0)publishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: d1c7f7 [27.06. 13:56]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo