Publication:
Patient characteristics, predictors and outcome of pacemaker patients upgraded to an implantable cardioverter defibrillator.

cris.virtual.author-orcid0000-0002-2296-4631
cris.virtual.author-orcid0000-0002-0050-5717
cris.virtual.author-orcid0000-0002-7197-8415
cris.virtual.author-orcid0000-0002-9283-0110
cris.virtual.author-orcid0000-0002-0827-1329
cris.virtualsource.author-orcidb61fed5f-9520-4db9-b5ad-31436c5c0228
cris.virtualsource.author-orcid4e9e3be2-2179-47d0-b502-06ea01c37b85
cris.virtualsource.author-orcid3735b256-1299-40f0-adf8-d273bca48312
cris.virtualsource.author-orcid0f1f3e5c-0328-4ed7-9213-517a61969ec9
cris.virtualsource.author-orcida63ed03a-5763-419e-ae4b-189464965bfa
cris.virtualsource.author-orcid47ad88bb-91b4-4f4e-8697-875fadb6a2c6
cris.virtualsource.author-orcid9794fdac-0a25-4701-b826-ac565e84a1c9
cris.virtualsource.author-orcid4c166ead-37ac-4728-a644-84cddba30915
cris.virtualsource.author-orcid4bc32805-3a2b-46f9-87ca-488cdf3d3dc0
cris.virtualsource.author-orcidd4e9c4f7-2e60-452d-8dfa-7e8b6a4f6098
datacite.rightsopen.access
dc.contributor.authorBaldinger, Samuel Hannes
dc.contributor.authorBurren, Désirée
dc.contributor.authorNoti, Fabian
dc.contributor.authorServatius, Helge Simon
dc.contributor.authorSeiler, Jens
dc.contributor.authorMadaffari, Antonio
dc.contributor.authorAsatryan, Babken
dc.contributor.authorTanner, Hildegard
dc.contributor.authorReichlin, Tobias Roman
dc.contributor.authorHäberlin, Andreas David Heinrich
dc.contributor.authorRoten, Laurent
dc.date.accessioned2025-01-08T21:34:59Z
dc.date.available2025-01-08T21:34:59Z
dc.date.issued2024-06
dc.description.abstractAIMS Pacemaker (PM) patients may require a subsequent upgrade to an implantable cardioverter defibrillator (ICD). Limited data exists on this patient population. We sought to characterize this population, to assess predictors for ICD upgrade, and to report the outcome. METHODS From our prospective PM and ICD implantation registry, all patients who underwent PM and/or ICD implantations at our center were analyzed. Patient characteristics and outcomes of PM patients with subsequent ICD upgrade were compared to age- and sex-matched patients with de novo ICD implantation, and to PM patients without subsequent upgrade. RESULTS Of 1'301 ICD implantations, 60 (5%) were upgraded from PMs. Median time from PM implantation to ICD upgrade was 2.6 years (IQR 1.3-5.4). Of 2'195 PM patients, 28 patients underwent subsequent ICD upgrades, corresponding to an estimated annual incidence of an ICD upgrade of at least 0.33%. Lower LVEF (p = .05) and male sex (p = .038) were independent predictors for ICD upgrade. Survival without death, transplant and LVAD implantation were worse both for upgraded ICD patients compared to matched patients with de novo ICD implantation (p = .05), as well as for PM patients with subsequent upgrade compared to matched PM patients not requiring an upgrade (p = .036). CONCLUSIONS One of 20 ICD implantations are upgrade of patients with a PM. At least one of 30 PM patients will require an ICD upgrade in the following 10 years. Predictors for ICD upgrade are male sex and lower LVEF at PM implantation. Upgraded patients have worse outcomes.
dc.description.numberOfPages9
dc.description.sponsorshipUniversitätsklinik für Kardiologie
dc.identifier.doi10.48350/196211
dc.identifier.pmid38655610
dc.identifier.publisherDOI10.1111/pace.14988
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/202569
dc.language.isoen
dc.publisherWiley
dc.relation.ispartofPacing and clinical electrophysiology
dc.relation.issn1540-8159
dc.relation.organizationDCD5A442BC3CE17DE0405C82790C4DE2
dc.relation.organizationDCD5A442BB15E17DE0405C82790C4DE2
dc.subjectimplantable cardioverter defibrillator mortality pacemaker risk factors upgrade
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titlePatient characteristics, predictors and outcome of pacemaker patients upgraded to an implantable cardioverter defibrillator.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage861
oaire.citation.issue6
oaire.citation.startPage853
oaire.citation.volume47
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliation2sitem Zentrum für Translationale Medizin und Biomedizinisches Unternehmertum
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2024-04-26 13:48:45
unibe.description.ispublishedpub
unibe.eprints.legacyId196211
unibe.journal.abbrevTitlePacing Clin Electrophysiol
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Pacing_Clinical_Electrophis_-_2024_-_Baldinger_-_Patient_characteristics__predictors_and_outcome_of_pacemaker_patients.pdf
Size:
1.17 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by-nc/4.0
Content:
published

Collections