Fluorescence lifetime distribution in phakic and pseudophakic healthy eyes.
Options
BORIS DOI
Publisher DOI
PubMed ID
36608033
Description
PURPOSE
To investigate the influence of the lens status and to describe fundus autofluorescence lifetimes (FLT) in a large cohort of healthy eyes across a wide age range.
MATERIALS AND METHODS
FLT data were acquired from healthy phakic and pseudophakic eyes using fluorescence lifetime imaging ophthalmoscopy (FLIO). Retinal autofluorescence was excited with a 473 nm laser and emitted autofluorescence was detected in a short and a long spectral channel (SSC: 498-560 nm; LSC: 560-720 nm).
RESULTS
141 healthy eyes from 141 participants (56 ± 18 years) were included. The shortest mean FLTs were measured within the macular center, followed by the temporal inner and outer ETDRS (Early Treatment Diabetic Retinopathy Study) grid segments, and the remaining areas of the inner and the outer ETDRS ring. In phakic participants (81%), mean, short and long FLTs correlated with the age (SSC: r2 = 0.54; LSC: r2 = 0.7; both p<0.0001) with an increase of about 33 ps in the SSC resp. 28 ps in the LSC per decade. In pseudophakic subjects (19%), mean FLTs only correlated with age in the long spectral channel (r2 = 0.44; p = 0.0002) but not in the short spectral channel (r2 = 0.066; p = 0.2).
CONCLUSIONS
Fundus autofluorescence lifetimes are age dependent. FLTs in the SSC are more susceptible to lens opacities but less dependent on age changes, whereas FLTs in the LSC are largely independent of the lens status but display a higher degree of age dependency.
STUDY REGISTRY
ClinicalTrials.gov NCT01981148.
To investigate the influence of the lens status and to describe fundus autofluorescence lifetimes (FLT) in a large cohort of healthy eyes across a wide age range.
MATERIALS AND METHODS
FLT data were acquired from healthy phakic and pseudophakic eyes using fluorescence lifetime imaging ophthalmoscopy (FLIO). Retinal autofluorescence was excited with a 473 nm laser and emitted autofluorescence was detected in a short and a long spectral channel (SSC: 498-560 nm; LSC: 560-720 nm).
RESULTS
141 healthy eyes from 141 participants (56 ± 18 years) were included. The shortest mean FLTs were measured within the macular center, followed by the temporal inner and outer ETDRS (Early Treatment Diabetic Retinopathy Study) grid segments, and the remaining areas of the inner and the outer ETDRS ring. In phakic participants (81%), mean, short and long FLTs correlated with the age (SSC: r2 = 0.54; LSC: r2 = 0.7; both p<0.0001) with an increase of about 33 ps in the SSC resp. 28 ps in the LSC per decade. In pseudophakic subjects (19%), mean FLTs only correlated with age in the long spectral channel (r2 = 0.44; p = 0.0002) but not in the short spectral channel (r2 = 0.066; p = 0.2).
CONCLUSIONS
Fundus autofluorescence lifetimes are age dependent. FLTs in the SSC are more susceptible to lens opacities but less dependent on age changes, whereas FLTs in the LSC are largely independent of the lens status but display a higher degree of age dependency.
STUDY REGISTRY
ClinicalTrials.gov NCT01981148.
Date of Publication
2023
Publication Type
Article
Subject(s)
Language(s)
en
Contributor(s)
Additional Credits
Series
PLoS ONE
Publisher
Public Library of Science
ISSN
1932-6203
Access(Rights)
open.access