• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Total Body PET/CT: Clinical Value and Future Aspects of Quantification in Static and Dynamic Imaging
 

Total Body PET/CT: Clinical Value and Future Aspects of Quantification in Static and Dynamic Imaging

Options
  • Details
  • Files
BORIS DOI
10.48620/86065
Publisher DOI
10.1053/j.semnuclmed.2024.11.004
PubMed ID
39616013
Description
Total body (TB) Positron Emission Tomography (PET) / Computed Tomography (CT) scanners have revolutionized nuclear medicine by enabling whole-body imaging in a single bed position.1 This review assesses the physical and clinical value of TB-PET/CT, with a focus on the advancements in both static and dynamic imaging, as well as the evolving quantification techniques. The significantly enhanced sensitivity of TB scanners can reduce radiation exposure and scan time, offering improved patient comfort and making it particularly useful for pediatric imaging and various other scenarios. Shorter scan times also decrease motion artifacts, leading to higher-quality images and better diagnostic accuracy. Dynamic PET imaging with TB scanners extends these advantages by capturing temporal changes in tracer uptake over time, providing real-time insights into both structural and functional assessment, and promoting the ability to monitor disease progression and treatment response. We also present CT-free attenuation correction methods that utilize the increased sensitivity of TB-PET as a potential improvement for dynamic TB-PET protocols. In static imaging, emerging quantification techniques such as dual-tracer PET using TB scanners allow imaging of two biological pathways, simultaneously, for a more comprehensive assessment of disease. In addition, positronium imaging, a novel technique utilizing positronium lifetime measurements, is introduced as a promising aspect for providing structural information alongside functional quantification. Finally, the potential of expanding clinical applications with the increased sensitivity of TB-PET/CT scanners is discussed.
Date of Publication
2025-01
Publication Type
Article
Language(s)
en
Contributor(s)
Rathod, Narendra
Clinic of Nuclear Medicine
Jutidamrongphan, Warissara
Clinic of Nuclear Medicine
Bosbach, Wolfram Andreas
Clinic of Nuclear Medicine
Chen, Yizhou
Clinic of Nuclear Medicine
Penner, Jan Luca
Clinic of Nuclear Medicine
Sari, Hasan
Clinic of Nuclear Medicine
Zeimpekis, Konstantinos
Clinic of Nuclear Medicine
López Montes, Alejandro
Clinic of Nuclear Medicine
Moskal, Pawel
Stepien, Ewa
Shi, Kuangyuorcid-logo
Clinic of Nuclear Medicine
Rominger, Axelorcid-logo
Clinic of Nuclear Medicine
Seifert, Robert
Clinic of Nuclear Medicine
Additional Credits
Clinic of Nuclear Medicine
Series
Seminars in Nuclear Medicine
Publisher
Elsevier
ISSN
0001-2998
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo