Publication:
Clinical and Hemodynamic Outcomes of Balloon-Expandable Mitral Valve-in-Valve Positioning and Asymmetric Deployment: The VIVID Registry.

cris.virtualsource.author-orcid101f1394-72d5-4dda-b28f-666a3dee6c70
cris.virtualsource.author-orcidb7cda86d-8924-42a5-973a-d73fee5c630b
cris.virtualsource.author-orcid093687ae-09e2-4fb7-9644-881258cb30f4
cris.virtualsource.author-orcid5509b63b-1ffa-42e1-ae2c-567fe2f87a20
datacite.rightsrestricted
dc.contributor.authorSimonato, Matheus
dc.contributor.authorWhisenant, Brian K
dc.contributor.authorUnbehaun, Axel
dc.contributor.authorKempfert, Jörg
dc.contributor.authorRibeiro, Henrique B
dc.contributor.authorKornowski, Ran
dc.contributor.authorErlebach, Magdalena
dc.contributor.authorBleiziffer, Sabine
dc.contributor.authorWindecker, Stephan
dc.contributor.authorPilgrim, Thomas
dc.contributor.authorTomii, Daijiro
dc.contributor.authorGuerrero, Mayra
dc.contributor.authorAhmad, Yousif
dc.contributor.authorForrest, John K
dc.contributor.authorMontorfano, Matteo
dc.contributor.authorAncona, Marco
dc.contributor.authorAdam, Matti
dc.contributor.authorWienemann, Hendrik
dc.contributor.authorFinkelstein, Ariel
dc.contributor.authorVillablanca, Pedro
dc.contributor.authorCodner, Pablo
dc.contributor.authorHildick-Smith, David
dc.contributor.authorFerrari, Enrico
dc.contributor.authorPetronio, Anna Sonia
dc.contributor.authorShamekhi, Jasmin
dc.contributor.authorPresbitero, Patrizia
dc.contributor.authorBruschi, Giuseppe
dc.contributor.authorRudolph, Tanja
dc.contributor.authorCerillo, Alfredo
dc.contributor.authorAttias, David
dc.contributor.authorNejjari, Mohammed
dc.contributor.authorAbizaid, Alexandre
dc.contributor.authorFelippi de Sá Marchi, Maurício
dc.contributor.authorHorlick, Eric
dc.contributor.authorWijeysundera, Harindra
dc.contributor.authorAndreas, Martin
dc.contributor.authorThukkani, Arun
dc.contributor.authorAgrifoglio, Marco
dc.contributor.authorIadanza, Alessandro
dc.contributor.authorBaer, L Matthew
dc.contributor.authorNanna, Michael G
dc.contributor.authorDvir, Danny
dc.date.accessioned2024-12-09T13:45:38Z
dc.date.available2024-12-09T13:45:38Z
dc.date.issued2023-11-13
dc.description.abstractBackground Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction.Objectives This study aimed to determine whether device position and asymmetry are associated with these outcomes.Methods Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated.Results A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027).Conclusions Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.
dc.description.sponsorshipClinic of Cardiology
dc.identifier.doi10.48620/77270
dc.identifier.pmid37968032
dc.identifier.publisherDOI10.1016/j.jcin.2023.08.047
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/191524
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofJACC: Cardiovascular Interventions
dc.relation.issn1876-7605
dc.relation.issn1936-8798
dc.subjectSAPIEN 3
dc.subjectdepth of implantation
dc.subjectleft ventricular outflow tract obstruction
dc.subjectmitral valve-in-valve
dc.subjectpositioning
dc.subjectresidual stenosis
dc.titleClinical and Hemodynamic Outcomes of Balloon-Expandable Mitral Valve-in-Valve Positioning and Asymmetric Deployment: The VIVID Registry.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage2627
oaire.citation.issue21
oaire.citation.startPage2615
oaire.citation.volume16
oairecerif.author.affiliationClinic of Cardiology
oairecerif.author.affiliationClinic of Cardiology
oairecerif.author.affiliationClinic of Cardiology
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.roleauthor
unibe.contributor.rolecorresponding author
unibe.description.ispublishedpub
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
1-s2.0-S193687982301316X-main.pdf
Size:
1.71 MB
Format:
Adobe Portable Document Format
File Type:
text
Content:
published

Collections