Publication:
Consensus-based technical recommendations for clinical translation of renal BOLD MRI.

cris.virtual.author-orcid0000-0001-8649-1098
cris.virtualsource.author-orcide9401515-a542-4d08-a375-8da12fe69df6
datacite.rightsopen.access
dc.contributor.authorBane, Octavia
dc.contributor.authorMendichovszky, Iosif A
dc.contributor.authorMilani, Bastien
dc.contributor.authorDekkers, Ilona A
dc.contributor.authorDeux, Jean-Francois
dc.contributor.authorEckerbom, Per
dc.contributor.authorGrenier, Nicolas
dc.contributor.authorHall, Michael E
dc.contributor.authorInoue, Tsutomu
dc.contributor.authorLaustsen, Christoffer
dc.contributor.authorLerman, Lilach O
dc.contributor.authorLiu, Chunlei
dc.contributor.authorMorrell, Glen
dc.contributor.authorPedersen, Michael
dc.contributor.authorPruijm, Menno
dc.contributor.authorSadowski, Elizabeth A
dc.contributor.authorSeeliger, Erdmann
dc.contributor.authorSharma, Kanishka
dc.contributor.authorThoeny, Harriet
dc.contributor.authorVermathen, Peter
dc.contributor.authorWang, Zhen J
dc.contributor.authorSerafin, Zbigniew
dc.contributor.authorZhang, Jeff L
dc.contributor.authorFrancis, Susan T
dc.contributor.authorSourbron, Steven
dc.contributor.authorPohlmann, Andreas
dc.contributor.authorFain, Sean B
dc.contributor.authorPrasad, Pottumarthi V
dc.date.accessioned2024-10-28T18:10:56Z
dc.date.available2024-10-28T18:10:56Z
dc.date.issued2020-02
dc.description.abstractHarmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as ≥ 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65-74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.
dc.description.numberOfPages17
dc.description.sponsorshipDIPR, Magnetresonanz-Spektroskopie und Methodologie (AMSM)
dc.identifier.doi10.7892/boris.138074
dc.identifier.pmid31768797
dc.identifier.publisherDOI10.1007/s10334-019-00802-x
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/185458
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofMagma
dc.relation.issn1352-8661
dc.relation.organizationMagnetic Resonance Spectroscopy and Methodology (MSM)
dc.relation.organizationInstitute of Diagnostic, Interventional and Paediatric Radiology
dc.relation.organizationDepartment for BioMedical Research (DBMR)
dc.relation.organizationDepartment for BioMedical Research, Abt. Magnetresonanz-Spektroskopie und Methodologie, AMSM
dc.subjectBOLD MRI Biomarkers Consensus Imaging Kidney Standardization
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleConsensus-based technical recommendations for clinical translation of renal BOLD MRI.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage215
oaire.citation.issue1
oaire.citation.startPage199
oaire.citation.volume33
oairecerif.author.affiliationDIPR, Magnetresonanz-Spektroskopie und Methodologie (AMSM)
oairecerif.author.affiliation2Department for BioMedical Research, Abt. Magnetresonanz-Spektroskopie und Methodologie, AMSM
oairecerif.author.affiliation3Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.embargoChanged2023-11-26 23:25:03
unibe.date.licenseChanged2020-01-27 07:15:42
unibe.description.ispublishedpub
unibe.eprints.legacyId138074
unibe.refereedtrue
unibe.subtype.articlereview

Files

Original bundle
Now showing 1 - 1 of 1
Name:
consensus.pdf
Size:
983.11 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections