• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. 1-Year Outcomes of the CENTERA-EU Trial Assessing a Novel Self-Expanding Transcatheter Heart Valve.
 

1-Year Outcomes of the CENTERA-EU Trial Assessing a Novel Self-Expanding Transcatheter Heart Valve.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.139147
Publisher DOI
10.1016/j.jcin.2019.01.231
PubMed ID
30947942
Description
OBJECTIVES

The purpose of this study is to report the 1-year results of the CENTERA-EU trial.

BACKGROUND

The CENTERA transcatheter heart valve (THV) (Edwards Lifesciences, Irvine, California) is a low-profile (14-F eSheath compatible), self-expanding nitinol valve, with a motorized delivery system allowing for repositionability. The 30-day results of the CENTERA-EU trial demonstrated the short-term safety and effectiveness of the valve.

METHODS

Implantations were completed in 23 centers in Europe, Australia, and New Zealand. Transfemoral access was used in all patients. Echocardiographic outcomes were adjudicated by a core laboratory at baseline, discharge, 30 days, 6 months, and 1 year. Major adverse clinical events were adjudicated by an independent clinical events committee.

RESULTS

Between March 2015 and July 2016, 203 high-risk patients (age 82.7 ± 5.5 years, 67.5% women, 68.0% New York Heart Association functional class III or IV, Society of Thoracic Surgeons score 6.1 ± 4.2%) with severe, symptomatic aortic stenosis underwent transcatheter aortic valve replacement with the CENTERA THV. The primary endpoint of the study was 30-day mortality (1.0%). At 1 year, overall mortality was 9.1%, cardiovascular mortality was 4.6%, disabling stroke was 4.1%, new permanent pacemakers were implanted in 6.5% of patients at risk, and cardiac-related rehospitalization was 6.8%. Hemodynamic parameters were stable at 1 year, with a mean aortic valve gradient of 8.1 ± 4.7 mm Hg, a mean effective orifice area of 1.7 ± 0.42 cm2, and no incidences of severe or moderate aortic regurgitation.

CONCLUSIONS

The CENTERA-EU trial demonstrated mid-term safety and effectiveness of the CENTERA THV, with low mortality, sustained improvements in hemodynamic performances, and low incidence of permanent pacemaker implantations in high-risk patients with symptomatic aortic stenosis. (Safety and Performance of the Edwards CENTERA-EU Self-Expanding Transcatheter Heart Valve [CENTERA-2]; NCT02458560).
Date of Publication
2019-04-08
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
CENTERA THV aortic stenosis high-risk patients self-expanding valve transcatheter aortic valve implantation
Language(s)
en
Contributor(s)
Tchétché, Didier
Windecker, Stephan
Universitätsklinik für Kardiologie
Kasel, A Markus
Schaefer, Ulrich
Worthley, Stephen
Linke, Axel
Abdel-Wahab, Mohamed
Le Breton, Herve
Søndergaard, Lars
Spence, Mark S
Petronio, Sonia
Baumgartner, Helmut
Hovorka, Tomas
Blanke, Philipp
Reichenspurner, Hermann
Additional Credits
Universitätsklinik für Kardiologie
Series
JACC. Cardiovascular Interventions
Publisher
Elsevier
ISSN
1876-7605
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo