  3. Predicting the impact of target volume contouring variations on the organ at risk dose: results of a qualitative survey
 

Predicting the impact of target volume contouring variations on the organ at risk dose: results of a qualitative survey

Options
  • Details
  • Files
BORIS DOI
10.48620/88945
Publisher DOI
10.1016/j.radonc.2025.110999
Description
Purpose
Integrating auto-contouring in radiotherapy workflows is shifting the role of radiation oncologists from manual delineation to reviewing and correcting automatically generated contours. However, we postulate that this process is hindered by significant inter-evaluator variability in assessing the dosimetric impact of contour variations. This study investigates how radiation oncologists and medical physicists evaluate the impact of glioblastoma target volume (TV) variations on the dose to organs at risk (OARs), focusing on understanding inter-evaluator variability and decision-making patterns.
Methods
A qualitative survey was conducted involving four radiation oncologists and three medical physicists. Participants classified 54 glioblastoma TV contour variations using up to four changes each across 14 patients as “better,” “no change,” or “worse” regarding their expected impact on the dose to OARs. The corresponding ground truth labels were derived from standardized treatment plans. Inter-evaluator variability was analyzed using Cohen’s Kappa.
Results
Substantial variability was observed, with Cohen’s Kappa values ranging from weak to moderate agreement (0.33–0.74). Evaluators frequently overestimated the negative impact of contour variations, misclassifying 46% of “no change” variations as “Worse.” No evaluator judged contour variations as resulting in “better” doses to OARs, despite this being the case for 4 variations.
Conclusion
Significant variability in estimating the dosimetric impact of contour variations underscores the critical need for standardized guidelines to reduce inconsistencies and allow for the assessment of automatically generated contours based on clinically meaningful factors. Evaluators frequently overestimated the negative impact of contour variations, potentially leading to inefficiencies and unnecessary contour corrections in clinical practice.
Date of Publication
2025-06-30
Publication Type
Article
Keyword(s)
Contouring
•
Qualitative survey
•
Dosimetric impact
•
Inter-observer variability
Language(s)
en
Contributor(s)
Willmann, Jonas
Kamath, Amithorcid-logo
ARTORG Center - Artificial Intelligence in Medical Image Computing
ARTORG Center for Biomedical Engineering Research - Medical Image Analysis
Poel, Robertorcid-logo
Clinic of Radiation Oncology
Riggenbach, Elena
Clinic of Radiation Oncology
Mose, Lucas
Clinic of Radiation Oncology
Bertholet, Jenny
Clinic of Radiation Oncology
Muller, Silvan
Schmidhalter, Danielorcid-logo
Clinic of Radiation Oncology, Medical Radiation Physics
Andratschke, Nicolaus
Ermis, Ekin
Clinic of Radiation Oncology
Reyes, Mauricio
Clinic of Radiation Oncology, Medical Radiation Physics
ARTORG Center - Artificial Intelligence in Medical Image Computing
ARTORG Center for Biomedical Engineering Research - Medical Image Analysis
Additional Credits
Clinic of Radiation Oncology, Medical Radiation Physics
Clinic of Radiation Oncology
ARTORG Center - Artificial Intelligence in Medical Image Computing
ARTORG Center for Biomedical Engineering Research - Medical Image Analysis
Series
Radiotherapy & Oncology
Publisher
Elsevier
ISSN
0167-8140
Related Funding(s)
Swiss Cancer League
Access(Rights)
embargo
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo