Publication:
Gingival Thickness Assessment at Mandibular Incisors of Orthodontic Patients with Ultrasound and Cone-beam CT. A Cross-sectional Study.

cris.virtual.author-orcid0000-0002-0665-238X
cris.virtualsource.author-orcida7c6fd15-7822-4377-b3e4-6d41da9fb429
cris.virtualsource.author-orcidddeb752c-6f59-466e-a26d-7e9b0a6d84d4
cris.virtualsource.author-orcid8b9d9dbd-711a-478a-8309-7b1f80a17a56
datacite.rightsopen.access
dc.contributor.authorKloukos, Dimitrios
dc.contributor.authorKakali, Lydia
dc.contributor.authorKoukos, George
dc.contributor.authorSculean, Anton
dc.contributor.authorStavropoulos, Andreas
dc.contributor.authorKatsaros, Christos
dc.date.accessioned2024-09-02T17:27:46Z
dc.date.available2024-09-02T17:27:46Z
dc.date.issued2021-01-07
dc.description.abstractPURPOSE To use and evaluate two methods for measuring gingival thickness (GT) at mandibular incisors of orthodontic patients and compare their performance in assessing periodontal anatomy through soft tissue thickness. MATERIALS AND METHODS The sample consisted of 40 consecutive adult orthodontic patients. GT was measured just before bracket placement at both central mandibular incisors, mid-facially on the buccal aspect, 2 mm apically to the free gingival margin with two methods: clinically with an ultrasound device (USD) and radiographically with cone-beam computed tomography (CBCT). RESULTS CBCT measurements were consistently higher than USD measurements, with the difference ranging from 0.13 mm to 0.21 mm. No statistically significant difference was noted between the repeated CBCT measurements at the right central incisor (bias = 0.05 mm; 95% CI = -0.01, 0.11; p = 0.104). Although the respective results for the left incisor statistically indicated that the measurements were not exactly replicated, the magnitude of the point estimate was small and not clinically significant (bias = 0.06 mm; 95% CI = 0.01, 0.11; p = 0.014). Small differences between CBCT measurements made by the 2 examiners at the left central incisor (bias = 0.06 mm; 95% CI = 0.01, 0.11; p = 0.014) were detected. However, this difference was minor and also not clinically significant. The respective analysis on the right incisor showed no statistically significant difference (bias = 0.05 mm; 95% CI = -0.01, 0.11; p = 0.246). CONCLUSIONS Based on reproducibility, CBCT imaging for gingival thickness assessment proved to be as reliable as ultrasound determination. However, CBCT consistently yielded higher values, albeit at a marginal level, than did the ultrasound device.
dc.description.numberOfPages8
dc.description.sponsorshipZahnmedizinische Kliniken, Klinik für Kieferorthopädie
dc.description.sponsorshipZahnmedizinische Kliniken, Klinik für Parodontologie
dc.identifier.doi10.48350/155993
dc.identifier.pmid33881289
dc.identifier.publisherDOI10.3290/j.ohpd.b1248965
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/41942
dc.language.isoen
dc.publisherQuintessenz Verlags-GmbH
dc.relation.ispartofOral health & preventive dentistry
dc.relation.issn1602-1622
dc.relation.organizationDCD5A442C013E17DE0405C82790C4DE2
dc.relation.organizationDCD5A442B9BDE17DE0405C82790C4DE2
dc.subjectcone-beam CT gingival phenotype periodontal tissue ultrasound
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleGingival Thickness Assessment at Mandibular Incisors of Orthodontic Patients with Ultrasound and Cone-beam CT. A Cross-sectional Study.
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage270
oaire.citation.issue1
oaire.citation.startPage263
oaire.citation.volume19
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Kieferorthopädie
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Parodontologie
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Kieferorthopädie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2021-05-25 11:29:21
unibe.description.ispublishedpub
unibe.eprints.legacyId155993
unibe.journal.abbrevTitleOral Health Prev Dent
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
ohpd_2021_01_s0263.pdf
Size:
439.28 KB
Format:
Adobe Portable Document Format
License:
https://creativecommons.org/licenses/by/4.0
Content:
published

Collections