• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Computer simulations of sample preconcentration in carrier-free systems and isoelectric focusing in microchannels using simple ampholytes.
 

Computer simulations of sample preconcentration in carrier-free systems and isoelectric focusing in microchannels using simple ampholytes.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.81581
Publisher DOI
10.1002/elps.201500120
PubMed ID
26036978
Description
In this work, electrophoretic preconcentration of protein and peptide samples in microchannels was studied theoretically using the 1D dynamic simulator GENTRANS, and experimentally combined with MS. In all configurations studied, the sample was uniformly distributed throughout the channel before power application, and driving electrodes were used as microchannel ends. In the first part, previously obtained experimental results from carrier-free systems are compared to simulation results, and the effects of atmospheric carbon dioxide and impurities in the sample solution are examined. Simulation provided insight into the dynamics of the transport of all components under the applied electric field and revealed the formation of a pure water zone in the channel center. In the second part, the use of an IEF procedure with simple well defined amphoteric carrier components, i.e. amino acids, for concentration and fractionation of peptides was investigated. By performing simulations a qualitative description of the analyte behavior in this system was obtained. Neurotensin and [Glu1]-Fibrinopeptide B were separated by IEF in microchannels featuring a liquid lid for simple sample handling and placement of the driving electrodes. Component distributions in the channel were detected using MALDI- and nano-ESI-MS and data were in agreement with those obtained by simulation. Dynamic simulations are demonstrated to represent an effective tool to investigate the electrophoretic behavior of all components in the microchannel.
Date of Publication
2015-08-03
Publication Type
Article
Keyword(s)
Isoelectric focusing
•
Mass spectrometry
•
Microchip
•
Preconcentration
•
Simulation
Language(s)
en
Contributor(s)
Mikkonen, Saara
Thormann, Wolfgang
Institut für Infektionskrankheiten, Labor für Klinische Pharmakologie
Emmer, Åsa
Additional Credits
Institut für Infektionskrankheiten, Labor für Klinische Pharmakologie
Series
Electrophoresis
Publisher
Wiley-VCH
ISSN
0173-0835
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo