  1. Home
  2. Publications
  3. In Vitro Biomechanical Comparison of Four Different Ventral Surgical Procedures on the Canine Fourth-Fifth Cervical Vertebral Motion Unit.

In Vitro Biomechanical Comparison of Four Different Ventral Surgical Procedures on the Canine Fourth-Fifth Cervical Vertebral Motion Unit.

Details
Publisher DOI
10.1055/s-0038-1667200
PubMed ID
30235472
Abstract
INTRODUCTION

 Biomechanical properties of four different ventral surgical procedures at the canine fourth-fifth cervical (C4-C5) vertebral motion unit (VMU) were assessed and compared with the intact C4-C5 VMU.

MATERIALS AND METHODS

 The third-sixth cervical vertebral column from 24 skeletally mature Beagle cadavers were randomly allocated to four groups (standard ventral slot, slanted slot, inverted cone slot and intervertebral disc fenestration). Standardized tests were performed for each specimen in flexion/extension, lateral bending and axial rotation. The specimens were tested intact and after completion of one of the three slots techniques or fenestration. Pre-testing, cadaver specimens were confirmed to be free of disease by computed tomography (CT) examination. Post-testing, dimensions of slots and fenestration were determined based on a second CT examination.

RESULTS

 All ventral surgical procedures increased range of motion (ROM) at the C4-C5 VMU compared with intact specimens. The only significant difference in the increase in ROM was observed between slanted slot and fenestration in flexion/extension. The standard ventral slot had a significant higher increase in ROM in extension compared with the other three techniques. The slanted slot had a significant lower increase in ROM in flexion.

DISCUSSION/CONCLUSION

 The described ventral slot techniques have similar biomechanical effects on the canine cervical vertebral column. In contrast to the findings of a previous study, the slanted slot and inverted cone slot do not appear to provide a biomechanical benefit compared with standard ventral slot.
Date Issued
2018-11
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Author(s)
Hermann, Andreas  
Departement für klinische Veterinärmedizin, Kleintierklinik  
Voumard, Benjamin  
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Waschk, Maja Alice  
Departement klinische Veterinärmedizin, Klinische Radiologie  
Hettlich, Bianca Felicitas  
Departement für klinische Veterinärmedizin, Kleintierklinik  
Forterre, Franck  
Departement für klinische Veterinärmedizin, Kleintierklinik  
Additional Credits
Departement klinische Veterinärmedizin, Klinische Radiologie  
Departement für klinische Veterinärmedizin, Kleintierklinik  
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Journal
Veterinary and comparative orthopaedics and traumatology
Publisher
Thieme
ISSN
0932-0814
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify