  2. Publications
  3. Ten-Year Results of the Fitmore Hip Stem with a Focus on Varus/Valgus Alignment and Subsidence-A Retrospective Monocentric Analysis.

Ten-Year Results of the Fitmore Hip Stem with a Focus on Varus/Valgus Alignment and Subsidence-A Retrospective Monocentric Analysis.

Details
Files
DOI
10.48620/76011
Publisher DOI
10.3390/jcm13185570
PubMed ID
39337057
Abstract
Hip arthroplasty is a common elective surgery worldwide, with rising numbers due to demographic changes and an emphasis on maintaining physical activity in the elderly. The development of new implant designs, especially shorter uncemented stems, has contributed to the advancement of minimally invasive implantation techniques. However, the long-term in vivo behaviour of these implants, particularly regarding subsidence, stability, and stress shielding, remains to be fully understood. This retrospective, monocentric cohort study analyses the long-term radiographic outcomes of the first 141 patients who underwent total hip arthroplasty with the Fitmore Hip Stem between June 2007 and December 2008. It focuses on subsidence, stability, varus-valgus alignment, and the influence of patient-related, anatomical, and surgical factors on implant behaviour over a 10-year follow-up period. The average change in varus/valgus alignment was 0.7° into varus and the average subsidence was 1.7 mm over 10 years, with most changes occurring within the first six weeks postoperatively. The varus-valgus alignment and subsidence did not significantly change after the first year, indicating stable osteointegration of the implant. Neither patient factors (gender, age) nor surgical and implant factors (implantation angle, approach, stem family, size, total offset) had a significant influence on the long-term behaviour of the implant. The Fitmore Hip Stem shows highly reliable long-term stability and integration, unaffected by various patient, surgical, and implant factors, as confirmed by excellent register data. Nevertheless, monitoring of this and other new implants should be continued in order to determine implant behaviour, possible weaknesses, and indication limits at an early stage for the benefit of the patient.
Date Issued
2024-09-20
Publication Type
Article
Subjects
hip replacement
•
long-term outcome
•
minimally invasive surgery
•
short stem
•
subsidence
•
total hip arthroplasty
Language(s)
en
Author(s)
Wanner, Ronald
Butler Ransohoff, Christopher  
Clinic of Orthopaedic Surgery  
Wyss, Tobias
Nötzli, Hubert
Additional Credits
Clinic of Orthopaedic Surgery  
Journal
Journal of Clinical Medicine
Publisher
MDPI
ISSN
2077-0383
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify