• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Measurements of greenhouse gases at Beromünster tall-tower station in Switzerland

Measurements of greenhouse gases at Beromünster tall-tower station in Switzerland

Details
Files
DOI
10.7892/boris.87547
Publisher DOI
10.5194/amt-9-2603-2016
Abstract
In order to constrain the regional flux of greenhouse gases, an automated measurement system was built on an old radio tower at Beromünster, Switzerland. The measurement system has been running since November 2012 as part of the Swiss greenhouse gases monitoring network (CarboCount-CH), which is composed of four measurement sites across the country. The Beromünster tall tower has five sampling lines with inlets at 12.5, 44.6, 71.5, 131.6, and 212.5 m above ground level, and it is equipped with a Picarro cavity ring-down spectrometer (CRDS) analyzer (G-2401), which continuously measures CO, CO₂, CH₄, and H₂O. Sensors for detection of wind speed and direction, air temperature, barometric pressure, and humidity have also been installed at each height level. We have observed a non-negligible temperature effect in the calibration measurements, which was found to be dependent on the type of cylinder (steel or aluminum) as well as trace gas species (strongest for CO). From a target gas of known mixing ratio that has been measured once a day, we have calculated a long-term reproducibility of 2.79 ppb, 0.05 ppm, and 0.29 ppb for CO, CO₂, and CH₄, respectively, over 19 months of measurements. The values obtained for CO₂ and CH₄ are compliant with the WMO recommendations, while the value calculated for CO is higher than the recommendation. Since the installation of an air-conditioning system recently at the measurement cabin, we have acquired better temperature stability of the measurement system, but no significant improvement was observed in the measurement precision inferred from the target gas measurements. Therefore, it seems that the observed higher variation in CO measurements is associated with the instrumental noise, compatible with the precision provided by the manufacturer.
Date Issued
2016
Publication Type
Article
Subject(s)
500 Science > 530 Physics
500 Science > 550 Earth sciences & geology
Language(s)
en
Author(s)
Berhanu, Tesfaye Ayalneh
Satar, Ece  
Physikalisches Institut, Klima- und Umweltphysik (KUP)  
Schanda, Rudiger
Nyfeler, Peter  
Physikalisches Institut, Klima- und Umweltphysik (KUP)  
Moret, Hanspeter  
Physikalisches Institut, Klima- und Umweltphysik (KUP)  
Brunner, Dominik
Oney, Brian
Leuenberger-Lüthy, Markus Christian  
Physikalisches Institut, Klima- und Umweltphysik (KUP)  
Oeschger Centre for Climate Change Research (OCCR)  
Additional Credits
Physikalisches Institut, Klima- und Umweltphysik (KUP)  
Oeschger Centre for Climate Change Research (OCCR)  
Journal
Atmospheric Measurement Techniques (AMT)
Publisher
Copernicus Publications
ISSN
1867-1381
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify