• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Non-Invasive Assessment of Intra-Abdominal Pressure Using Ultrasound Guided Tonometry - a Proof-of-Concept Study.
 

Non-Invasive Assessment of Intra-Abdominal Pressure Using Ultrasound Guided Tonometry - a Proof-of-Concept Study.

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.108685
Publisher DOI
10.1097/SHK.0000000000001085
PubMed ID
29251669
Description
BACKGROUND

Intra-abdominal hypertension jeopardizes abdominal organ perfusion and venous return. Contemporary recognition of elevated intra-abdominal pressure (IAP) plays a crucial role in reducing mortality and morbidity. We evaluated ultrasound guided tonometry in this context hypothesizing that the vertical chamber diameter of this device inversely correlates with intra-abdominal pressure.

METHODS

IAP was increased in six 5 mmHg steps to 40 mmHg by instillation of normal saline into the peritoneal cavity of eight anesthetized pigs. Liver and renal blood flows (ultrasound transit time), intra-vesical, intra-peritoneal and end-inspiratory plateau pressures were recorded. For ultrasound-based assessment of intra-abdominal pressure (ultrasound guided tonometry), a pressure transducing, compressible chamber was fixed at the tip of a linear ultrasound probe, and the system was applied on the abdominal wall using different pre-determined levels of external pressure. At each IAP level (reference: intra-vesical pressure), two investigators measured the vertical diameter of this chamber.

RESULTS

All abdominal flows decreased (by 39% to 58%), and end-inspiratory plateau pressure increased from 15 mbar (14-17 mbar) to 38 mbar (33-42 mbar) (median, range) with increasing IAP (all p < 0.01). Vertical chamber diameter decreased from 14.9 (14.6-15.2) mm to12.8 (12.4-13.4) mm with increasing IAP. Coefficients of variations between and within observers regarding change of the vertical tonometry chamber diameter were small (all < 4%), and the results were independent of the externally applied pressure level on the ultrasound probe. Correlation of IAP and vertical pressure chamber distance was highly significant (r: -1, p: 0.0004). Ultrasound guided tonometry could discriminate between normal (baseline) pressure and 15 mmHg, between 15 and 25mmHg) and between 25 and 40 mmHg IAP (all p≤0.18). Similar results were obtained for end-inspiratory plateau pressures.

CONCLUSIONS

In our model, values obtained by ultrasound guided tonometry correlated significantly with intra-abdominal pressures. The method was able to discriminate between normal, moderately and markedly increased IAP values.
Date of Publication
2018-12
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Bloch, Andreas
Universitätsklinik für Intensivmedizin
Glas, Michael
Universitätsklinik für Intensivmedizin
Kohler, Andreasorcid-logo
Department for BioMedical Research, Forschungsgruppe Viszeralchirurgie
Universitätsklinik für Viszerale Chirurgie und Medizin, Viszeral- und Transplantationschirurgie
Baumann, Ulrich
Jakob, Stephan
Universitätsklinik für Intensivmedizin
Additional Credits
Universitätsklinik für Intensivmedizin
Department for BioMedical Research, Forschungsgruppe Viszeralchirurgie
Series
Shock
Publisher
Lippincott Williams & Wilkins
ISSN
1073-2322
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo