• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Optimal tension of fascia lata graft with SuturePatch augmentation in superior capsule reconstruction for irreparable tears of the supraspinatus and infraspinatus tendons.

Optimal tension of fascia lata graft with SuturePatch augmentation in superior capsule reconstruction for irreparable tears of the supraspinatus and infraspinatus tendons.

Details
Files
DOI
10.48620/96070
Publisher DOI
10.1016/j.jseint.2025.101611
PubMed ID
41732421
Abstract
Background
Postoperative graft tear is correlated with poor clinical outcome after superior capsule reconstruction (SCR) for irreparable rotator cuff tears. The objective of this study was to investigate the optimal tension of the SuturePatch, which has been developed to reinforce SCR.
Methods
Eight fresh-frozen cadaveric shoulders were tested by using a custom shoulder-testing system. Superior glenohumeral translation, subacromial peak contact pressure, and glenohumeral range of motion (ROM) were compared among 4 conditions: (1) intact; (2) irreparable supraspinatus and infraspinatus tears; (3) SCR using a thin fascia lata graft and SuturePatch augmentation performed at 20° glenohumeral abduction; and (4) SCR using the same graft with SuturePatch augmentation performed at 30° glenohumeral abduction.
Results
Increased superior glenohumeral translation and subacromial peak contact pressure after creation of an irreparable supraspinatus and infraspinatus tendon tear significantly decreased after SCR with SuturePatch augmentation performed at both 20° and 30° glenohumeral abduction. Superior glenohumeral translation and subacromial peak contact pressure did not differ between 20° and 30° glenohumeral abductions. Internal rotation (P = .39-.99), external rotation (P = .61-.99), or total rotational ROM (P = .51-.99) were comparable between the irreparable supraspinatus and infraspinatus tendon tear condition and SCR with SuturePatch augmentation at both 20° and 30° glenohumeral abduction.
Conclusion
SCR with SuturePatch augmentation restored superior glenohumeral stability and maintained glenohumeral ROM. When the SuturePatch is used to augment the graft of SCR, 30° or 45° of shoulder abduction (equal to 20° or 30° of glenohumeral abduction) may provide the optimal tension for graft attachment to the glenoid medially and greater tuberosity laterally.
Date Issued
2026-03
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Augmentation
•
Biomechanics
•
Cadaver study
•
Superior capsule reconstruction
•
SuturePatch
•
Tension
Language(s)
en
Author(s)
Mihata, Teruhisa
Chalmers, Christen E
Carbone, Joseph
Maniglio, Mauro  
Künzler, Michael  
Clinic of Orthopaedic Surgery  
Patel, Nilay A
Fujisawa, Yukitaka
McGarry, Michelle H
Lee, Thay Q
Additional Credits
Clinic of Orthopaedic Surgery  
Journal
JSES International
Publisher
Elsevier
ISSN
2666-6383
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify