  3. Reliability of lithium dilution cardiac output in anaesthetized sheep
 

Reliability of lithium dilution cardiac output in anaesthetized sheep

Options
  • Details
  • Files
BORIS DOI
10.7892/boris.48110
Publisher DOI
10.1093/bja/aet220
PubMed ID
23838805
Description
BACKGROUND:
Cardiac output (CO) measurement with lithium dilution (COLD) has not been fully validated in sheep using precise ultrasonic flow probe technology (COUFP). Sheep generate important cardiovascular research models and the use of COLD has become more popular in experimental settings.

METHODS:
Ultrasonic transit-time perivascular flow probes were surgically implanted on the pulmonary artery of 13 sheep. Paired COLD readings were taken at six time points, before and after implantation of a left ventricular assist device (LVAD) and compared with COUFP recorded just after lithium injection.

RESULTS:
The mean COLD was 5.7 litre min(-1) (range 3.8-9.6 litre min(-1)) and mean COUFP 5.9 litre min(-1) (range 4.0-9.2 litre min(-1)). The bias (standard deviation) was 0.3 (1.0) litre min(-1) [5.1 (16.9)%] and limits of agreement (LOA) were -1.7 to 2.3 litre min(-1) (-28.8 to 39.0%) with a percentage error (PE) of 34.4%. Data to assess trending [rate (95% confidence intervals)] included a 78 (62-93)% concordance rate in the four-quadrant plot (n=27). In the half moon polar plot (n=19), the mean polar angle was +5°, the radial LOA were -49 to +35° and 68 (47-89)% of data points fell within 22.5° of the mean polar angle. Both tests indicated moderate to poor trending ability.

CONCLUSION:
COLD is not precise when evaluated against COUFP in sheep based on the statistical criteria set, but the results are comparable with previously published animal studies.

KEYWORDS:
Date of Publication
2013
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
anaesthesia
•
veterinary
•
data interpretation
•
statistical
•
measurement techniques
•
cardiac output
•
measurement techniques
•
lithium dilution
•
sheep
Language(s)
en
Contributor(s)
Axiak, Shannonorcid-logo
Departement klinische Veterinärmedizin, Anästhesiologie
Critchley, L. A.
Weber, Alberto
Universitätsklinik für Herz- und Gefässchirurgie
Pirbodaghi, Tohid
ARTORG Center - Cardiovascular Engineering (Heart)
Most, Henriette
Universitätsklinik für Herz- und Gefässchirurgie
Vandenberghe, Stijn
ARTORG Center - Cardiovascular Engineering (Heart)
Additional Credits
Departement klinische Veterinärmedizin, Anästhesiologie
Universitätsklinik für Herz- und Gefässchirurgie
ARTORG Center - Cardiovascular Engineering (Heart)
Series
British journal of anaesthesia
Publisher
Oxford University Press
ISSN
0007-0912
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo