  3. Cardiopulmonary performance testing using a robotics-assisted tilt table: Feasibility assessment in able-bodied subjects
 

Cardiopulmonary performance testing using a robotics-assisted tilt table: Feasibility assessment in able-bodied subjects

Options
  • Details
Publisher DOI
10.3233/THC-140783
Description
BACKGROUND:
Robotics-assisted tilt table technology was introduced for early rehabilitation of neurological patients. It provides cyclical stepping movement and physiological loading of the legs. The aim of the present study was to assess the feasibility of this type of device for peak cardiopulmonary performance testing using able-bodied subjects.
METHODS:
A robotics-assisted tilt table was augmented with force sensors in the thigh cuffs and a work rate estimation algorithm. A custom visual feedback system was employed to guide the subjects' work rate and to provide real time feedback of actual work rate. Feasibility assessment focused on: (i) implementation (technical feasibility), and (ii) responsiveness (was there a measurable, high-level cardiopulmonary reaction?). For responsiveness testing, each subject carried out an incremental exercise test to the limit of functional capacity with a work rate increment of 5 W/min in female subjects and 8 W/min in males.
RESULTS:
11 able-bodied subjects were included (9 male, 2 female; age 29.6 ± 7.1 years: mean ± SD). Resting oxygen uptake (O<formula>_{2}</formula>) was 4.6 ± 0.7 mL/min/kg and O<formula>_{2}</formula>peak was 32.4 ± 5.1 mL/min/kg; this mean O<formula>_{2}</formula>peak was 81.1% of the predicted peak value for cycle ergometry. Peak heart rate (HRpeak) was 177.5 ± 9.7 beats/min; all subjects reached at least 85% of their predicted HRpeak value. Respiratory exchange ratio (RER) at O<formula>_{2}</formula>peak was 1.02 ± 0.07. Peak work rate) was 61.3 ± 15.1 W. All subjects reported a Borg CR10 value for exertion and leg fatigue of 7 or more.
CONCLUSIONS:
The robotics-assisted tilt table is deemed feasible for peak cardiopulmonary performance testing: the approach was found to be technically implementable and substantial cardiopulmonary responses were observed. Further testing in neurologically-impaired subjects is warranted.
Date of Publication
2014-01-01
Publication Type
Article
Subject(s)
500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
600 Technology > 620 Engineering
Keyword(s)
Rehabilitation
•
cardiopulmonary performance testing
•
rehabilitation robotics
•
tilt table
Language(s)
en
Contributor(s)
Saengsuwan, Jittima
ARTORG Center for Biomedical Engineering Research
Laubacher, M
Nef, Tobiasorcid-logo
ARTORG - Gerontechnology and Rehabilitation
Hunt, KJ
Additional Credits
ARTORG Center for Biomedical Engineering Research
ARTORG - Gerontechnology and Rehabilitation
Series
Technology and health care
Publisher
IOS Press
ISSN
0928-7329
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo