  3. Trueness and precision of combined healing abutment-scan body system depending on the scan pattern and implant location: an in-vitro study.
 

Trueness and precision of combined healing abutment-scan body system depending on the scan pattern and implant location: an in-vitro study.

Options
  • Details
  • Files
BORIS DOI
10.48350/170473
Publisher DOI
10.1016/j.jdent.2022.104169
PubMed ID
35661761
Description
OBJECTIVE

To test the effect of scan pattern and the location of the implant on the trueness and precision of implant scans when the combined healing abutment-scan body (CHA-SB) system is used.

MATERIAL AND METHODS

A partially edentulous maxillary model with CHA-SBs secured on implants at 3 different sites in the left quadrant (central incisor, first premolar, and first molar) was fabricated. The model was scanned with an industrial light scanner to generate a master reference model (MRM) file. An intraoral scanner (TRIOS 3) was used to perform the test scans (n=8) with 4 different scan patterns (SP1, SP2, SP3, and SP4) with an intraoral scanner. The test scans were superimposed over the MRM file with a metrology software to calculate the distance deviations of the CHA-SB system. Data were analyzed with a 2-way analysis of variance and Tukey's honestly significant difference tests for accuracy (α=.05).

RESULTS

Trueness (P=.001) and precision (P=.018) were significantly affected by the interaction between the scan pattern and implant location. The implant located at the central incisor site (56.7 ±35.9, 36.2 ±18.6) had higher trueness than that of located at the premolar site (94.1 ±20.4, 100.3 ±20) when SP2 (P=.037) and SP4 (P=.002) were used. The implant at the molar site (71.9 ±25.7, 147.2 ±49.7) had trueness either similar to (when SP2 was used, P≥.276) or lower than (when SP4 was used, P≤.024) those of others. Scans of the central incisor and premolar implants had the lowest trueness when scanned with SP1 (P≤.009), while the scans of molar implant showed higher trueness when performed by using SP2 and SP3 when compared with SP4 (P≤.005). When SP4 was used, the implant at the molar site had lower precision (43 ±18.9) than the implants located at the central incisor (14.1 ±11) and premolar sites (15.4 ±11.3) (P=.002). Scan patterns affected the scan precision of central incisor implant (P=.009), as SP4 (14.1 ±11) led to a higher precision than SP1 (47.7 ±27) (P=.006).

CONCLUSIONS

The scan accuracy of combined healing abutment-scan body system was affected by scan pattern and implant location. SP1, which involved palatal and rotational scans resulted in the lowest trueness for central incisor and premolar implants, while the scans of the central incisor implant showed the highest trueness among different sites when SP4 was used. However, the scan pattern and implant site had a minor effect on precision. Scan precision at different implant sites only differed when SP4 was used, which resulted in the lowest precision for molar implant.
Date of Publication
2022-09
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Accuracy Combined healing abutment-scan body Implant position Scan pattern
Language(s)
en
Contributor(s)
Dönmez, Mustafa-Borga
Zahnmedizinische Kliniken (ZMK)
Cakmak, Gülce
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Atalay, Sevda
Yilmaz, Hakan
Yilmaz, Burak
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Additional Credits
Zahnmedizinische Kliniken, Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin
Zahnmedizinische Kliniken (ZMK)
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Series
Journal of dentistry
Publisher
Elsevier Science
ISSN
0300-5712
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo