Comparison of the analgesic potency of xenon and nitrous oxide in humans evaluated by experimental pain.
Options
BORIS DOI
Publisher DOI
Description
We have compared the analgesic potency of MAC-equivalent concentrations of xenon (10, 20, 30 and 40%) and nitrous oxide (15, 30, 45 and 60%) in humans using a multimodal experimental pain testing and assessment technique. We tested 12 healthy volunteers in a randomized, single-blind, crossover study. The following experimental pain tests were used: nociceptive reflex to repeated stimuli; pain tolerance to maximal effort tourniquet ischaemia; electrical stimulation; mechanical pressure; and cold. Reaction time was also measured. Xenon and nitrous oxide produced analgesia to ischaemic, electrical and mechanical stimulation, but not to cold pain. There was no difference in MAC-equivalent concentrations of xenon and nitrous oxide. Both increased reaction time in a similar manner. Xenon and nitrous oxide evoked nausea and vomiting in a large number of volunteers.
Date of Publication
1998
Publication Type
Article
Subject(s)
Language(s)
en
Contributor(s)
Schnider, T. W. | |
Arendt-Nielsen, L. |
Additional Credits
Series
British journal of anaesthesia
Publisher
Oxford University Press
ISSN
0007-0912
Access(Rights)
open.access