Inverse thermodilution with conventional pulmonary artery catheters for the assessment of cerebral, hepatic, renal, and femoral blood flow

Details
Publisher DOI
10.1097/SHK.0b013e318194c73a
PubMed ID
19033887
Abstract
Assessment of regional blood flow changes is difficult in the clinical setting. We tested whether conventional pulmonary artery catheters (PACs) can be used to measure regional venous blood flows by inverse thermodilution (ITD). Inverse thermodilution was tested in vitro and in vivo using perivascular ultrasound Doppler (USD) flow probes as a reference. In anesthetized pigs, PACs were inserted in jugular, hepatic, renal, and femoral veins, and their measurements were compared with simultaneous USD flow measurements from carotid, hepatic, renal, and femoral arteries and from portal vein. Fluid boluses were injected through the PAC's distal port, and temperature changes were recorded from the proximally located thermistor. Injectates of 2 and 5 mL at 22 degrees C and 4 degrees C were used. Flows were altered by using a roller pump (in vitro), and infusion of dobutamine and induction of cardiac tamponade, respectively. In vitro: At blood flows between 400 mL . min-1 and 700 mL . min-1 (n = 50), ITD and USD correlated well (r = 0.86, P < 0.0001), with bias and limits of agreement of 3 +/- 101 mL . min-1. In vivo: 514 pairs of measurements had to be excluded from analysis for technical reasons, and 976 were analyzed. Best correlations were r = 0.87 (P < 0.0001) for renal flow and r = 0.46 (P < 0.0001) for hepatic flow. No significant correlation was found for cerebral and femoral flows. Inverse thermodilution using conventional PAC compared moderately well with USD for renal but not for other flows despite good in vitro correlation in various conditions. In addition, this method has significant technical limitations.
Date Issued
2009
Publication Type
Article
Language(s)
en
Author(s)
Ganter, Christoph  
Universitätsklinik für Intensivmedizin  
Buser, Christof
Hänggi, Matthias  
Universitätsklinik für Intensivmedizin  
Mattes, Hanswilly  
Universitätsklinik für Intensivmedizin  
Takala, Jukka  
Universitätsklinik für Intensivmedizin  
Jakob, Stephan  
Universitätsklinik für Intensivmedizin  
Additional Credits
Universitätsklinik für Intensivmedizin  
Journal
Shock
Publisher
Lippincott Williams & Wilkins
ISSN
1073-2322
ISBN
19033887
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify