  1. Home
  2. Publications
  3. Objective assessment of patient compliance with removable orthodontic appliances: a cross-sectional cohort study.

Objective assessment of patient compliance with removable orthodontic appliances: a cross-sectional cohort study.

Details
Files
DOI
10.7892/boris.60516
Publisher DOI
10.2319/042313-315.1
PubMed ID
23834273
Abstract
OBJECTIVE

To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors.

MATERIALS AND METHODS

Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex.

RESULTS

There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58).

CONCLUSIONS

Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.
Date Issued
2014-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Patient compliance
•
Removable orthodontic appliances
•
TheraMon
Language(s)
en
Author(s)
Tsomos, George
Ludwig, Björn
Grossen, Johannes  
Zahnmedizinische Kliniken, Klinik für Kieferorthopädie  
Pazera, Pawel  
Zahnmedizinische Kliniken, Klinik für Kieferorthopädie  
Gkantidis, Nikolaos  
Zahnmedizinische Kliniken, Klinik für Kieferorthopädie  
Additional Credits
Zahnmedizinische Kliniken, Klinik für Kieferorthopädie  
Journal
Angle orthodontist
Publisher
Angle Orthodontists Research and Education Foundation
ISSN
0003-3219
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify