Objective assessment of patient compliance with removable orthodontic appliances: a cross-sectional cohort study.
Publisher DOI
PubMed ID
23834273
Abstract
OBJECTIVE
To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors.
MATERIALS AND METHODS
Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex.
RESULTS
There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58).
CONCLUSIONS
Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.
To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors.
MATERIALS AND METHODS
Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex.
RESULTS
There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58).
CONCLUSIONS
Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.
Date Issued
2014-01
Publication Type
Article
Subject(s)
Subjects
Patient compliance
•
Removable orthodontic appliances
•
TheraMon
Language(s)
en
Additional Credits
Journal
Angle orthodontist
Publisher
Angle Orthodontists Research and Education Foundation
ISSN
0003-3219
Access(Rights)