• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Real-Time Fluoroscopic Assessment of Underexpansion Predicts Hemodynamic Valve Deterioration Following TAVR With Balloon-Expandable Device.

Real-Time Fluoroscopic Assessment of Underexpansion Predicts Hemodynamic Valve Deterioration Following TAVR With Balloon-Expandable Device.

Details
Files
DOI
10.48620/92759
Publisher DOI
10.1016/j.jcin.2025.10.005
PubMed ID
41240026
Abstract
Background
The clinical sequelae of transcatheter heart valve (THV) underexpansion following transcatheter aortic valve replacement (TAVR) with balloon-expandable devices remain incompletely understood.Objectives
The aim of this study was to investigate the impact of THV underexpansion on clinical outcomes among patients treated with balloon-expandable TAVR.Methods
Consecutive patients undergoing transfemoral TAVR with the SAPIEN 3 and SAPIEN 3 Ultra systems in the prospective Bern TAVI registry were retrospectively evaluated. THV underexpansion was assessed on postimplantation fluoroscopic images and quantified using the validated commissural post height method. Significant THV underexpansion was defined as a reduction in stent frame midportion diameter ≥20% compared with the nominal diameter, using an optimal cutoff value determined by maximizing the log-rank statistic. The outcomes of interest were moderate or severe hemodynamic valve deterioration (HVD) according to the Valve Academic Research Consortium 3 and all-cause and cardiovascular mortality at 5-year follow-up.Results
Among 1,043 patients (median age 81 years; Q1-Q3: 76-85 years; 34.6% women) undergoing TAVR with SAPIEN 3 or SAPIEN 3 Ultra valves between 2014 and 2022, 57 (5.4%) exhibited THV underexpansion. THV underexpansion ≥ 20% was associated with an increased risk for HVD at 5-year follow-up (subdistribution HR: 4.88; 95% CI: 2.18-10.97). The risk for HVD gradually increased with increasing degree of underexpansion (subdistribution HR: 1.94 per 5% increase; 95% CI: 1.42-2.79), with consistent findings across all valve sizes. Total aortic valve calcium volume, bicuspid anatomy, and valve iteration were significant predictors of THV underexpansion. At 862-day follow-up (Q1-Q3: 366-1,812 days), underexpansion was not associated with mortality.Conclusions
Underexpansion of balloon-expandable THVs is associated with an increased risk for HVD at mid-term follow-up.
Date Issued
2025-12-22
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
TAVR
•
hemodynamic valve deterioration
•
underexpansion
Language(s)
en
Author(s)
Angellotti, Domenico  
Clinic of Cardiology  
Elamin, Nadir  
Ferro, Cyril  
Clinic of Cardiology  
Tomii, Daijiro  
Clinic of Cardiology  
Lanz, Jonas  
Clinic of Cardiology  
Stortecky, Stefan  
Clinic of Cardiology  
Alaour, Bashir
Bartkowiak, Joanna  
Clinic of Cardiology  
Samim, Daryoush  
Clinic of Cardiology  
Praz, Fabien  
Clinic of Cardiology  
Reineke, David  
Muller, Olivier  
Windecker, Stephan  
Clinic of Cardiology  
Clinic of Cardiology  
Meier, David
Pilgrim, Thomas  
Clinic of Cardiology  
Additional Credits
Clinic of Cardiology  
Journal
JACC: Cardiovascular Interventions
Publisher
Elsevier
ISSN
1876-7605
1936-8798
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify